针对磷脱氧铜管与低碳钢储罐钎焊后漏气失效问题,采用金相、扫描电镜(SEM)和能谱分析(EDAX)对失效器件进行分析,发现铜管漏气的主要原因是由于钎焊过程中,预热和钎焊工艺不恰当,导致焊接气氛交替出现氧化性和还原性,使得铜管发生氢脆,产生裂纹。同时在加热和冷却时,由于异种材料的热胀系数差别过大,产生的较大热应力作用于已存在的裂纹,促使裂纹二次扩展,甚至使得晶粒脱落产生空洞,最终导致焊接接头漏气失效。提出了合理控制燃气比、钎焊加热时间和焊后冷却时间,以改善钎焊质量的建议。
Abstract
The gas leakage failure of braze welding between the phosphorus deoxidized copper tube and stock tank of low carbon steel was investigated by means of metallography, SEM and EDAX analysis. Results show that the brittle fracture is mainly caused by hydrogen brittleness that results from the oxidation and absorbing hydrogen of copper tube during braze welding. Methods of brazing quality improvement are suggested as well.
中图分类号 TM201.4+6
所属栏目
基金项目
收稿日期 2005/6/30
修改稿日期
网络出版日期
作者单位点击查看
备注贾延琳(1982-),男,硕士研究生。
引用该论文: JIA Yan-lin,WANG Ming-pu,LI Zhou. CRACKING ANALYSIS OF BRAZED PHOSPHORUS DEOXIDIZED COPPER TUBE[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2006, 42(2): 92~94
贾延琳,汪明朴,李周. 磷脱氧铜管焊接漏气失效分析[J]. 理化检验-物理分册, 2006, 42(2): 92~94
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】姚 伟,何耀祖,姜也为.空调用铜管穿孔失效分析[J].理化检验-物理分册, 2002,40(9):471-473.
【2】田泽生.铜管钎焊热裂纹形成的原因与分析[J].制冷与空调, 2002,4(2):71-72.
【3】YS/T 335-1994,电真空器件用无氧铜含氧量金相检验法[S].
【4】洛阳铜加工厂中心实验室金相组.统计铜合金金相图谱[M].北京:冶金工业出版社, 1983.17,28.
【5】有色金属及其热处理编写组.有色金属及其热处理[M].北京:国防工业出版社, 1981.269-276.
【6】钱 红,李西恭,王增宏.高温焊接紫铜管脆断原因分析[J].北京工业大学学报, 1994,20(9):85-90.
【2】田泽生.铜管钎焊热裂纹形成的原因与分析[J].制冷与空调, 2002,4(2):71-72.
【3】YS/T 335-1994,电真空器件用无氧铜含氧量金相检验法[S].
【4】洛阳铜加工厂中心实验室金相组.统计铜合金金相图谱[M].北京:冶金工业出版社, 1983.17,28.
【5】有色金属及其热处理编写组.有色金属及其热处理[M].北京:国防工业出版社, 1981.269-276.
【6】钱 红,李西恭,王增宏.高温焊接紫铜管脆断原因分析[J].北京工业大学学报, 1994,20(9):85-90.
相关信息