FAILURE ANALYSIS OF THE FASTENING BOLT OF THE VALVE ON THE GAS TOWER
摘 要
储气塔运行半年即发生了阀门紧固螺栓的断裂事故。采用化学成分分析、硬度测定、金相检验以及断口的宏、微分析等方法,对螺栓断裂原因进行了分析。结果表明,由于塔内腐蚀性介质的微量渗出,导致了阀门紧固螺栓的应力腐蚀断裂。
Abstract
Fastening bolts at valve on gas tower was cracked after used 6 months. The failure analysis of the bolt was made by chemical composition,hardness,microstrcture examination and macrostrcture,SEM,EDX analysis for the fracture. The results show that the stress crrosion,wich is duo to the less leaking of the crrosion media in tower,cause the fastening bolt of valve failure.
中图分类号 TE986
所属栏目 质量控制与失效分析
基金项目
收稿日期 2006/8/22
修改稿日期
网络出版日期
作者单位点击查看
备注谷志刚(1954-),男,教授级高级工程师,学士。
引用该论文: GU Zhi-gang,HAO De-zhong,LI Wei-hang. FAILURE ANALYSIS OF THE FASTENING BOLT OF THE VALVE ON THE GAS TOWER[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2007, 43(3): 147~149
谷志刚,郝德中,李伟航. 储气塔阀门紧固螺栓的断裂分析[J]. 理化检验-物理分册, 2007, 43(3): 147~149