APPLICATION OF THE LAICA AUTO ANALYZING SOFTWARE FOR NON-METAL INCLUSION IN THE PRODUCTION
摘 要
引进的徕卡非金属夹杂物自动分析软件能对夹杂物迅速而准确地进行有统计性意义的测定和数据处理。通过一年多的摸索,对软件的开发应用取得了突破性的进展,填补了笔者单位在夹杂物定量分析这个领域中的空白,目前已开始应用在生产和科研中。
Abstract
By means of the Laika automatic analysis software,non-metallic inclusion can be tested accurately and quickly data treatment and measurement by statistical method. After one year practice,the software application developed in a significant advance. It filled up the blank in the field of inclusion quantitative analysis. Now the software is applied in the production and research.
中图分类号 TG115.21+3.1 TP311.5
所属栏目 试验技术与方法
基金项目
收稿日期 2005/7/18
修改稿日期
网络出版日期
作者单位点击查看
备注吕佐明(1958-),女,高级工程师。
引用该论文: L Zuo-ming,SUN Jian-ping. APPLICATION OF THE LAICA AUTO ANALYZING SOFTWARE FOR NON-METAL INCLUSION IN THE PRODUCTION[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2007, 43(6): 299~302
吕佐明,孙建平. 徕卡非金属夹杂物自动分析软件在生产中的应用[J]. 理化检验-物理分册, 2007, 43(6): 299~302