RECENT DEVELOPMENT OF CONTACT ANGLE MEASUREMENT TECHNIQUE
摘 要
接触角是材料表面润湿性能的重要参数之一。通过接触角的测量可以获得材料表面固-液、固-气界面相互作用的许多信息。介绍了几种常见的接触角的测量方法,并详细介绍了接触角测量技术所取得的最新研究成果。
Abstract
Contact angle is one of the most important parameters to characterize materials surface wetting property. A lot of useful information about the interface of solid-liquid or solid-vapor can be acquired,through the measurement of contact angle. The common contact angles measurements were described and the recent development of the contact angle measurement techniques were reviewed.
中图分类号 O552.4+21
所属栏目 综述
基金项目 湖北大学有机功能分子合成与应用省部共建教育部重点实验室开放课题基金(2006-KL-008)
收稿日期 2007/4/24
修改稿日期
网络出版日期
作者单位点击查看
备注丁晓峰(1982-),男,硕士研究生。
引用该论文: DING Xiao-feng,GUAN Rong,CHEN Pei-zhi. RECENT DEVELOPMENT OF CONTACT ANGLE MEASUREMENT TECHNIQUE[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2008, 44(2): 84~89
丁晓峰,管 蓉,陈沛智. 接触角测量技术的最新进展[J]. 理化检验-物理分册, 2008, 44(2): 84~89
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】Santos,Mohamed,Bannwart,et al. Contact angle measurements and wetting behavior of inner surfaces of pipelines exposed to heavy crude oil and water[J]. J Petrol Eng,2006,51(1/2):9.
【2】Wouters,Ruiter. Contact-angle development of polymer melts[J]. Prog Org Coat,2003,48(2-4):207.
【3】Blake. The physics of moving wetting lines[J]. J Colloid Interf Sci,2006,299(1):1-13.
【4】郑群锁.低表面能防污涂料的进展[J].材料开发与应用,2001,16(1):33.
【5】沈 洁,董 昊,张永熙,等.溶胶-凝胶法制备二氧化钛薄膜的亲水性研究[J].真空科学与技术,2000,20(6):385.
【6】Tavana,Simon,Grundke,et al. Interpretation of contact angle measurements on two different fluoropolymers for the determination of solid surface tension[J]. J Colloid Interf Sci,2005,291(2):497-506.
【7】Smedley,Coles. A refractive tilting-plate technique for measurement of dynamic contact angles[J]. J Colloid Interf Sci,2005,286(1):310-311.
【8】Bateni,Susnar,Amirfazli,et al. A high-accuracy polynomial fitting approach to determine contact angles[J]. Colloid Surface A,2003,219(1/3):215-219.
【9】Stalder,Kulik,Sage,et al. A snake-based approach to accurate determination of both contact points and contact angles[J]. Colloid Surface A,2006,286(1-3):92-103.
【10】Dingle,Harris. A robust algorithm for the simultaneous parameter estimation of interfacial tension and contact angle from sessile drop profiles[J]. J Colloid Interf Sci,2005,286(2):670-680.
【11】Della,Maniglio,Morra,et al. The determination of a stable-equilibrium contact angle on heterogeneous and rough surfaces[J]. Colloid Surface A,2002,206(1-3):47-67.
【12】Yang,Lin. A method for correcting the contact angle from the method[J]. Colloid Surface A,2003,220(1-3):199-210.
【13】Bardos. Contact angle dependence of solid probe–liquid drop forces in AFM measurements[J]. Surf Sci,2002,517(1-3):157-176.
【14】Bashforth,Adams. An Attempt to Test the Theory of Capillary Action[M]. Cambridge: Cambridge University Press,1995:1892-1896.
【15】Cabezas,Bateni,Montaner,et al. A new method of image processing in the analysis of axisymmetric drop shapes[J]. Colloid Surface A,2005,255(1-3):193-200.
【16】Zuo Ding,Bateni,Hoorfar,et al. Improvement of interfacial tension measurement using a captive bubble in conjunction with axisymmetric dropshape analysis (ADSA)[J]. Colloid Surface A,2004,250(1/3):233-246.
【17】Tavana,Neumann. On the question of rate-dependence of contact angles[J]. Colloid Surface A,2006,282/283:256-262.
【18】Oliver,Huh,Mason. The apparent contact angles of liquids on finely-grooved solid surfaces-a SEM study[J]. J Adhes,1977,8(1):223-234.
【19】Kwok,Lin,Mui,et al. Low-rate dynamic and static contact angles and the determination of solid surface tensions[J]. Colloid Surface A,1996,116(1/2):63-77.
【20】Katoh,Tsao,Yamamoto,et al. A new method for measuring contact angle and liquid surface tension applying detachment of two-dimensional meniscus[J]. J Colloid Interf Sci,1998,202(1):54-62.
【2】Wouters,Ruiter. Contact-angle development of polymer melts[J]. Prog Org Coat,2003,48(2-4):207.
【3】Blake. The physics of moving wetting lines[J]. J Colloid Interf Sci,2006,299(1):1-13.
【4】郑群锁.低表面能防污涂料的进展[J].材料开发与应用,2001,16(1):33.
【5】沈 洁,董 昊,张永熙,等.溶胶-凝胶法制备二氧化钛薄膜的亲水性研究[J].真空科学与技术,2000,20(6):385.
【6】Tavana,Simon,Grundke,et al. Interpretation of contact angle measurements on two different fluoropolymers for the determination of solid surface tension[J]. J Colloid Interf Sci,2005,291(2):497-506.
【7】Smedley,Coles. A refractive tilting-plate technique for measurement of dynamic contact angles[J]. J Colloid Interf Sci,2005,286(1):310-311.
【8】Bateni,Susnar,Amirfazli,et al. A high-accuracy polynomial fitting approach to determine contact angles[J]. Colloid Surface A,2003,219(1/3):215-219.
【9】Stalder,Kulik,Sage,et al. A snake-based approach to accurate determination of both contact points and contact angles[J]. Colloid Surface A,2006,286(1-3):92-103.
【10】Dingle,Harris. A robust algorithm for the simultaneous parameter estimation of interfacial tension and contact angle from sessile drop profiles[J]. J Colloid Interf Sci,2005,286(2):670-680.
【11】Della,Maniglio,Morra,et al. The determination of a stable-equilibrium contact angle on heterogeneous and rough surfaces[J]. Colloid Surface A,2002,206(1-3):47-67.
【12】Yang,Lin. A method for correcting the contact angle from the method[J]. Colloid Surface A,2003,220(1-3):199-210.
【13】Bardos. Contact angle dependence of solid probe–liquid drop forces in AFM measurements[J]. Surf Sci,2002,517(1-3):157-176.
【14】Bashforth,Adams. An Attempt to Test the Theory of Capillary Action[M]. Cambridge: Cambridge University Press,1995:1892-1896.
【15】Cabezas,Bateni,Montaner,et al. A new method of image processing in the analysis of axisymmetric drop shapes[J]. Colloid Surface A,2005,255(1-3):193-200.
【16】Zuo Ding,Bateni,Hoorfar,et al. Improvement of interfacial tension measurement using a captive bubble in conjunction with axisymmetric dropshape analysis (ADSA)[J]. Colloid Surface A,2004,250(1/3):233-246.
【17】Tavana,Neumann. On the question of rate-dependence of contact angles[J]. Colloid Surface A,2006,282/283:256-262.
【18】Oliver,Huh,Mason. The apparent contact angles of liquids on finely-grooved solid surfaces-a SEM study[J]. J Adhes,1977,8(1):223-234.
【19】Kwok,Lin,Mui,et al. Low-rate dynamic and static contact angles and the determination of solid surface tensions[J]. Colloid Surface A,1996,116(1/2):63-77.
【20】Katoh,Tsao,Yamamoto,et al. A new method for measuring contact angle and liquid surface tension applying detachment of two-dimensional meniscus[J]. J Colloid Interf Sci,1998,202(1):54-62.
相关信息