扫一扫 加微信
首页 > 期刊论文 > 论文摘要
石英晶片X射线自动分选仪的理论设计
          
THEORETICALLY DESIGN FOR AUTOMATIC QUARTZ-SORTING MACHINE

摘    要
介绍了石英晶片X射线自动分选仪的理论设计,详细讨论了测量原理、测量误差和探测器前端挡板设计等问题。结果表明,利用φ旋转法同时测量(0 1 1 1)和(0 2 2 3)晶面的衍射线,可以同时测出XX′倾角和AT切角,实现了对石英晶片的自动准确分选。
标    签 石英晶片自动分选仪   AT切角   XX′倾角   automatic quartz-sorting machine   AT-cutting angle   XX′-tilt  
 
Abstract
An automatic quartz-sorting machine by X-ray diffraction was designed theoretically and several aspects,including measurement principle,measurement errors and design for front mask of detector,were discussed in detail. The results indicated that XX′-tilt and AT cutting angle can be accurately measured by the diffraction peaks of (0 1 1 1) and (0 2 2 3) lattice planes with φ-scan method.

中图分类号 TM22+9.1 O434.19

 
  中国光学期刊网论文下载说明


所属栏目 试验与研究

基金项目 江苏省自然科学基金资助项目(BK2006204);南京理工大学青年学者基金资助项目(Njust200403)

收稿日期 2008/1/16

修改稿日期

网络出版日期

作者单位点击查看

备注邓俊静(1986-),男,大学本科在读。

引用该论文: DENG Jun-jing,TAN Wei-shi,WU Xiao-shan. THEORETICALLY DESIGN FOR AUTOMATIC QUARTZ-SORTING MACHINE[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2008, 44(11): 595~599
邓俊静,谭伟石,吴小山. 石英晶片X射线自动分选仪的理论设计[J]. 理化检验-物理分册, 2008, 44(11): 595~599


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】Nestler B,Kuhr H-J,Hildebrandt G,et al. Novel use of a commercial goniometer for sorting round quartz blanks[J]. Meas Sci Technol,1991,2: 528-531.
 
【2】Bradaczek H,Hildebrandt G,Uebach W. The use of an X-ray three beam technique to improve the adjustment of bars for cutting[C]// Proceedings of IEEE International Frequency Control Symposium. Salt Lake City,Utah,U.S.A:\[s.n\] 1993: 416-419.
 
【3】Bradaczek H,Hildebrandt G. Applications of X-rays in the quartz-oscillator industry[J]. The Rigaku Journal,1997,14(1): 12-20.
 
【4】Morys B,Bradaczek H,Hildebrandt G. Improved Ω-scan for separate measurement of the true AT-cutting angles and X-miscutting angles for round quartz blanks[C]// Proceedings of IEEE International Frequency Control Symposium. Boston,Massachusetts,U.S.A:\[s.n\] 1994:237-240.
 
【5】Berger H,Bradaczek H,Hildebrandt G. Complete X-ray orientation determination of quartz bars using a small scanning range[C]// Proceedings of Joint Meeting EFTF-IEEE IFCS. Besancon,France:\[s.n\] 1999: 851-854.
 
【6】Berger H,Bradaczek H-A,Pinaowski H,et al. A new quartz-blank sorting machine including optical and extended X-ray inspection[C]// Proceedings of IEEE/EIA International Frequency Control Symposium and Exhibition. Kansas City,U.S.A:\[s.n\] 2000: 247-249.
 
【7】Bradaczek H. Automated X-ray sorting machine for round quartz blanks[C]// Proceedings of Forty-fifth Annual Symposium on Frequency Control. Los Angeles,U.S.A:\[s.n\] 1991:114-116.
 
相关信息
   标题 相关频次
无相关信息...