Testing and Analysis of the Leakage Cause in Turbine Condenser
摘 要
为查找凝汽器泄漏原因, 对已经发生泄漏的凝汽器钛管周围管进行了涡流检测。结合两个典型的涡流阻抗信号, 利用标准检测程序功能制作了标定曲线, 可准确计算钛管减薄量。结合视频功能, 得出影响凝汽器钛管泄漏的原因在于外壁缺陷与机组启停产生的应力共同作用, 而外壁缺陷的根源是与支撑隔板间的碰损, 支撑隔板安装的垂直度及每行的同心度影响着支撑隔板与钛管的装配间隙, 在机组运行中隔板会导致钛管的外壁缺陷。
Abstract
For seeking the cause of the leakage in turbine condenser, eddy current testing was applied in the titanium tube around the leakage tube. Combining the two typical eddy impedance signals and using the standard detection program, we can deduce the demarcating curve which can be used to calculate the thickness loss of titanium tube. The leakage of titanium tube lies in the tube defects and the stress on account of power unit startup and stop. Abrasion between the titanium tube and the separating plate causes the defects of titanium tube. The fixing vertical angle of separating plate and concentricity of the row affect the assemble clearance between the titanium tube and separating plate.
中图分类号 TG115.28
所属栏目 试验研究
基金项目
收稿日期 2008/11/24
修改稿日期
网络出版日期
作者单位点击查看
备注李鹏云(1973-), 男, 硕士, 从事电力系统锅炉压力容器技术监督和检验及汽轮机金属技术监督检验工作。
引用该论文: LI Peng-Yun,WANG Fei. Testing and Analysis of the Leakage Cause in Turbine Condenser[J]. Nondestructive Testing, 2010, 32(2): 119~121
李鹏云,王 飞. 汽轮机凝汽器泄漏的涡流检测与分析[J]. 无损检测, 2010, 32(2): 119~121
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】李景和.海水作为冷却介质的汽轮机凝汽器泄漏原因及对策[J].东北电力技术, 2006(3): 41-44.
【2】许立国 , 沈竞为.不锈钢凝汽器管的应用选择[J].山东电力技术, 2001(1): 20-24.
【2】许立国 , 沈竞为.不锈钢凝汽器管的应用选择[J].山东电力技术, 2001(1): 20-24.
相关信息