Magnetic Flux Leakage Testing for Corrosion of Atmospheric Storage Tanks Bottom Plate
摘 要
结合对多台储罐底板漏磁检测过程中所发现与总结的问题, 从扫查覆盖率的控制、缺陷方向性影响、底板剩磁影响、缺陷单板定位、超声方法复验和底板表面状况影响等六个方面, 对如何做好底板腐蚀漏磁检测工作提出了一些意见和建议。
Abstract
The present summary is about the problems encountered during the magnetic flux leaking(MFL) inspecting for many storage tanks. Six issues were discussed in brief including the controlling of the scanning coverage percentage, the directionality effect of defects, the effect of residual magnetism, the defect positioning on single floor, the rechecking cases using ultrasonic method and the effect of surface condition, etc. Some empirical recommendations and conclusions were proposed to promote the MFL inspection work of bottom floor corrosion.
中图分类号 TG115.28
所属栏目 实践经验
基金项目
收稿日期 2009/7/9
修改稿日期
网络出版日期
作者单位点击查看
备注陈 虎(1979-), 男, 博士, 工程师, 主要从事锅炉、压力容器等设备方面的结构强度、数值模拟、安全评价以及无损检验检测等方面的研究。
引用该论文: CHEN Hu,LIN Yuan-Long,ZHU Jin-Dan. Magnetic Flux Leakage Testing for Corrosion of Atmospheric Storage Tanks Bottom Plate[J]. Nondestructive Testing, 2010, 32(6): 450~453
陈 虎,林远龙,祝金丹. 常压储罐底板腐蚀漏磁检测[J]. 无损检测, 2010, 32(6): 450~453
被引情况:
【1】陈谋财,陈伯红,段庆儒,丁晖,朱琴, "新型地上储罐腐蚀检测技术及设备",无损检测 35, 27-30(2013)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】API 653—2001 Tank Inspection , Repair , Alteration , and Reconstruction[S].
【2】JB/T 10765—2007 无损检测 常压金属储罐漏磁检测方法[S].
【3】Santos J B, Perdigo F. Automatic defects classification-A contribution[J]. NDT and E International, 2001, 34(5): 313-318.
【4】Cameron N B. Recommended practice for magnetic flux leakage inspection of atmospheric storage tank floors[R]. UK: HSE Infoline, 2006: 21
【5】Marino A, Drury J C. A Comparison of the Magnetic Flux Leakage and Ultrasonic Methods in the Detection and Measurement of Corrosion Pitting in Ferrous Plate and Pipe[C]// 15th World Conference on Non-Destructive Testing. Rome: [s. n.], 2000: 701.
【2】JB/T 10765—2007 无损检测 常压金属储罐漏磁检测方法[S].
【3】Santos J B, Perdigo F. Automatic defects classification-A contribution[J]. NDT and E International, 2001, 34(5): 313-318.
【4】Cameron N B. Recommended practice for magnetic flux leakage inspection of atmospheric storage tank floors[R]. UK: HSE Infoline, 2006: 21
【5】Marino A, Drury J C. A Comparison of the Magnetic Flux Leakage and Ultrasonic Methods in the Detection and Measurement of Corrosion Pitting in Ferrous Plate and Pipe[C]// 15th World Conference on Non-Destructive Testing. Rome: [s. n.], 2000: 701.
相关信息