Identification of Ultrasonic Anamorphic Wave Caused by Cladding of Pressure Vessel of Nuclear Power Plant
摘 要
介绍了核电站压力容器堆焊层下焊缝超声检测时, 由于堆焊层的影响, 产生变型波反射的特例。分析了因堆焊层产生变型波的原理以及变型波的定位方法。在实际堆焊层试块上, 对提出的变型波定位方法进行了验证。验证结果证明了堆焊层变型波的理论分析以及定位方法的正确性。该方法对判别因变型波造成的伪缺陷具有普遍的应用价值。
Abstract
The anamorphic wave reflection caused by cladding was introduced when the welding under cladding was tested of pressure vessel of nuclear power plant. The causing principle of anamorphic wave and location method was analyzed. On a cladding weld, test was carried on for verifying the analysis. Verification results proved the accurate of the mentioned method which could widely used on the false single identification caused by anamorphic wave.
中图分类号 TG115.28
所属栏目 2010年远东无损检测论坛论文精选
基金项目
收稿日期
修改稿日期
网络出版日期
作者单位点击查看
备注余 哲(1982-), 男, 工程师, 主要从事核电站役前、在役自动化超声无损检测工作与研究。
引用该论文: YU Zhe,LIU Yang. Identification of Ultrasonic Anamorphic Wave Caused by Cladding of Pressure Vessel of Nuclear Power Plant[J]. Nondestructive Testing, 2010, 32(9): 707~709
余 哲,刘 洋. 核电站压力容器堆焊层下超声波探伤中变型波的识别[J]. 无损检测, 2010, 32(9): 707~709
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好