Quantitative Analytical Technique of Corrosion Defects on Pipeline with Insulation Based on Pulsed Magnetic Flux Leakage
摘 要
对带保温层管道腐蚀缺陷的检测中, 定量缺陷宽度、深度和体积是一个难点问题。提出了采用脉冲漏磁技术对带保温层管道腐蚀缺陷进行检测的方法。通过提取传感器感应信号不同的时域特征作为特征量, 分析了不同特征量随缺陷参数的变化规律, 得出对应关系式, 实现了对缺陷宽度、深度和体积的定量检测。试验结果证明了所采用方法的正确性和有效性。
Abstract
Quantification for width, depth and volume of defects on pipeline with insulation is a difficult problem. A method of using pulsed magnetic flux leakage technique on testing corrosion defects on pipeline was proposed. Different features in time-domain were extracted to analyze the variation of the features and parameters of the defects, then the quantification for width, depth and volume of the defects could be realized through the obtained formula of the variation. The validity of the new method was demonstrated by experimental results.
中图分类号 TG115.28
所属栏目 试验研究
基金项目 国家科技支撑计划资助项目(2006BAK02B02)
收稿日期 2009/10/20
修改稿日期
网络出版日期
作者单位点击查看
备注王韫江(1982-), 男, 硕士, 助理工程师, 主要从事测试计量技术及仪器研究。
引用该论文: WANG Yun-Jiang,WANG Xiao-Feng,DING Ke-Qin. Quantitative Analytical Technique of Corrosion Defects on Pipeline with Insulation Based on Pulsed Magnetic Flux Leakage[J]. Nondestructive Testing, 2010, 32(11): 884~888
王韫江,王晓锋,丁克勤. 基于脉冲漏磁理论的带保温层管道腐蚀缺陷定量分析技术[J]. 无损检测, 2010, 32(11): 884~888
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】林俊明, 林发炳, 林春景.隔热层下钢管壁厚脉冲涡流检测系统[J].无损探伤, 2006, 30(6): 26-27.
【2】李光海, 沈功田, 李鹤年.工业管道无损检测技术[J].无损检测, 2006, 28(2): 89-93.
【3】Sophian Ali, Tian Gui Yun, Zairi Sofiane. Pulsed magnetic flux leakage techniques for crack detection and characterisation[J]. Sensors and Actuators A, 2006(125): 186-191.
【4】Tian G Y, Sophian A. Study of magnetic sensors for pulsed eddy current techniques[J]. Insight, 2005, 47(5): 277-279.
【5】杨理践.管道漏磁在线检测技术[J].沈阳工业大学学报, 2005, 27(5): 522-525.
【6】陈重, 崔正勤.电磁场理论基础[M].北京: 北京理工大学出版社, 2003.
【7】Yang Binfeng, Luo Feilu, Han Dan. Pulsed eddy current technique used for nondestructive inspection of aging aircraft [J]. Insight-Nondestructive Testing and Condition Monitoring, 2006, 48(7): 411-414.
【2】李光海, 沈功田, 李鹤年.工业管道无损检测技术[J].无损检测, 2006, 28(2): 89-93.
【3】Sophian Ali, Tian Gui Yun, Zairi Sofiane. Pulsed magnetic flux leakage techniques for crack detection and characterisation[J]. Sensors and Actuators A, 2006(125): 186-191.
【4】Tian G Y, Sophian A. Study of magnetic sensors for pulsed eddy current techniques[J]. Insight, 2005, 47(5): 277-279.
【5】杨理践.管道漏磁在线检测技术[J].沈阳工业大学学报, 2005, 27(5): 522-525.
【6】陈重, 崔正勤.电磁场理论基础[M].北京: 北京理工大学出版社, 2003.
【7】Yang Binfeng, Luo Feilu, Han Dan. Pulsed eddy current technique used for nondestructive inspection of aging aircraft [J]. Insight-Nondestructive Testing and Condition Monitoring, 2006, 48(7): 411-414.
相关信息