GF-AAS DETERMINATION OF TRACES OF TIN IN WASTE GAS FROM REFUSE INCINERATION WITH ZEEMAN EFFECT-BACKGROUND CORRECTION
摘 要
采用钯加抗坏血酸溶液作为基体改进剂,用塞曼效应扣除背景,对消化后的垃圾焚烧废气滤筒直接进行测定.方法的检出限为100 pg,线性范围为0.2-4 ng,回收率为96.8%-102.0%.
Abstract
A GF-AAS method was established for the determination of trace amounts of tin in waste gas from refuse incineration.Palladium nitrate and ascorbic acid were selected as matrix modifier.Zeeman effect was used for the correction of background absorption.Detection limit of the method was 100 pg (3σ).Linearity was in the range of 10-200 μg·L-1.Results obtained by test for recovery were in the range 96.8%-102.0%.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2004/6/20
修改稿日期
网络出版日期
作者单位点击查看
备注杨泉(1971-),男,福州人,工程师,主要从事环境检测工作.
引用该论文: YANG Quan. GF-AAS DETERMINATION OF TRACES OF TIN IN WASTE GAS FROM REFUSE INCINERATION WITH ZEEMAN EFFECT-BACKGROUND CORRECTION[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2006, 42(4): 274~275
杨泉. 塞曼石墨炉原子吸收光谱法直接测定垃圾焚烧废气中锡[J]. 理化检验-化学分册, 2006, 42(4): 274~275