Determination of Trace Amounts of Lead and Chromium in Zinc-Plated Steel by ICP-MS with High Resolution
摘 要
研究了电感耦合等离子体质谱法测定镀锌钢板中痕量杂质元素铬和铅,可测定低至10-5%数量级的痕量铅和铬.用国家标准物质验证了方法的准确度,测定值与标准值吻合,回收率为95%~106%,相对标准偏差小于5%(n=7).
Abstract
High-resolution inductively coupled plasma mass spectrometry was applied to the determination of trace amounts of lead and chromium in zinc-plated steel plate.Contents at order of magnitude of 10-5% (mass percentage) can be determined by this method.In the application to the analysis of some standard samples,results found were in consistency with the standard or known values.Test for recovery was performed,the results obtained were in the range from 95% to 106%.Precision was also tested,and values of RSD′s (n=7) obtained were less than 5%.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2006/1/11
修改稿日期
网络出版日期
作者单位点击查看
备注聂玲清(1976- ),女,四川遂宁人,科研人员,理学硕士,主要从事分析测试研究工作.
引用该论文: NIE Ling-qing,JI Hong-ling. Determination of Trace Amounts of Lead and Chromium in Zinc-Plated Steel by ICP-MS with High Resolution[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2007, 43(8): 629~631
聂玲清,纪红玲. 电感耦合等离子体质谱法测定镀锌钢板中痕量铬和铅[J]. 理化检验-化学分册, 2007, 43(8): 629~631
被引情况:
【1】李秀娟,吴俊峰, "电感耦合等离子体质谱法测定金属板涂/镀层中铅和镉",理化检验-化学分册 47, 847-849(2011)
【2】李政军,方永康,刘能盛,杨蓓,李波平,刘丽芬,林宏雄,翟翠萍,郑建国, "电感耦合等离子体原子发射光谱法测定硅钢片涂层中铬",理化检验-化学分册 45, 1122-1123(2009)
【3】王鑫艳,吴小红,陆伟星,胡宏卫, "电感耦合等离子体原子发射光谱法测定镀锡板镀层中痕量铅",理化检验-化学分册 49, 1520-1521(2013)