ICP-MS Simultaneous Determination of Inorganic Elements in Loquat Leaves
摘 要
枇杷叶试样于聚四氟烯消解罐中加入硝酸及过氧化氢置于微波炉中加热消解,对所得试样溶液中的14种无机元素用电感耦合等离子体质谱法同时测定.在测定钙、锰、镁、磷及铁的试验中,测得其线性范围在0~200 μg·L-1之间,用标准加入法对所测定的14种无机元素作了回收试验,所得回收率在90%~110%之间.按规定要求测定14种无机元素的检出限,测得结果在0.002~0.4 μg·L-1之间.
Abstract
Sample of loquat leaves was digested with HNO3 and H2O2 in PTFE vessel heated in microwave oven.Fourteen inorganic elements in the sample solution were determined by ICP-MS.As shown by the data of determination of Ca,Mn,Mg,P and Fe,ranges of linearity were obtained in the range of 0-200 μg·L-1.Tests for recovery were carried out by standard addition method and values of recovery for the 14 elements determined were in the range of 90%-110%.Detection limits for these elements were in the range from 0.002 to 0.4 μg·L-1.
中图分类号 O657.63
所属栏目 工作简报
基金项目
收稿日期 2006/12/30
修改稿日期
网络出版日期
作者单位点击查看
备注赖国新(1965-),男,福建莆田人,副教授,硕士研究生,主要从事仪器分析教学和研究工作.
引用该论文: LAI Guo-xin,ZHUANG Zhi-xia,CHEN Cheng-xiang,CHEN Shi,WANG Xiao-ru. ICP-MS Simultaneous Determination of Inorganic Elements in Loquat Leaves[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2008, 44(6): 566~567
赖国新,庄峙厦,陈成祥,陈石,王小如. 电感耦合等离子体质谱法同时测定枇杷叶中多种无机元素[J]. 理化检验-化学分册, 2008, 44(6): 566~567
被引情况:
【1】郑翌,杨丹,潘煜辰,李亦奇,施敬文,冷桃花, "微波消解-电感耦合等离子体质谱法测定养生保健汤料包中16种稀土元素",理化检验-化学分册 51, 814-817(2015)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】祁俊生,徐辉碧,周井炎,等.植物类中药中微量元素的因子分析和聚类分析[J].分析化学,1998,26(11):1309-1314.
【2】陈浩,梁沛,胡斌,等.电感耦合等离子体原子发射光谱/质谱法在中药微量元素及形态分析中的应用[J].光谱学与光谱分析,2002,22(6):1019-1024.
【3】黄志勇,经媛元,杨妙峰,等.ICP-MS测定茶叶中微量元素含量及其溶出特性的研究[J].厦门大学学报:自然科学版,2003,42(5):621-625.
【4】章连香,符 斌,李华昌.电感耦合等离子体质谱法应用的进展[J]矿冶,2004,13(1):102-106.
【2】陈浩,梁沛,胡斌,等.电感耦合等离子体原子发射光谱/质谱法在中药微量元素及形态分析中的应用[J].光谱学与光谱分析,2002,22(6):1019-1024.
【3】黄志勇,经媛元,杨妙峰,等.ICP-MS测定茶叶中微量元素含量及其溶出特性的研究[J].厦门大学学报:自然科学版,2003,42(5):621-625.
【4】章连香,符 斌,李华昌.电感耦合等离子体质谱法应用的进展[J]矿冶,2004,13(1):102-106.