以微波溶样技术消解样品,采用正交试验设计优化冷原子吸收光谱法测定汞的试验条件,并对微波消解条件和共存离子的干扰进行了试验.试验表明:汞含量在30 μg·L-1范围内服从比耳定律,方法的检出限为0.13 μg·L-1,相对标准偏差为2.6%,回收率为97.6%~106.8%.
Abstract
A method of microwave-assisted digestion followed by cold vapour AAS determination of mercury in fish meal was proposed in this paper. Orthogonal designing was used for optimization of working parameters of AAS determination. Interferences of coexisting ions were studied. Experimental results showed that linear relationship between mercury concentration and absorbance ranged within 30 μg·L-1 was obtained. DL of the method was found to be 0.13 μg·L-1,and RSD was 2.6%. Recovery was in range of 97.6%-106.8%.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2007/4/28
修改稿日期
网络出版日期
作者单位点击查看
备注丁健华(1966-),男,广东省潮安县人,副教授,主要从事光谱分析研究.
引用该论文: DING Jian-hua,HONG Yin,LI Jia-xin,HUANG Mei-zhen. Microwave Assisted Sample Digestion-Cold Vapour AAS Determination of Mercury in Fish Meal[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2008, 44(9): 860~861
丁健华,洪茵,李加新,黄美珍. 微波消解样品-冷原子吸收光谱法测定鱼粉中微量汞[J]. 理化检验-化学分册, 2008, 44(9): 860~861
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王夔.生命科学中的微量元素:上卷[M].北京:中国计量出版社,1992.
【2】朱莲珍.人和动物的微量元素营养[M].青岛:青岛出版社,1994.
【3】Kingston H M,Jassie L B.分析化学中的微波制样技术原理及应用[M].郭振库译.北京:中国气象出版社,1998.
【4】孙玉岭,刘景振.微波溶样在元素检测方面的应用研究[J].中国公共卫生,2002,18(2):231-232.
【5】郑用熙.分析化学中的数理统计方法[M].北京:科学出版社,1986.
【6】刘晶,郑楚光,徐杰英.微波消解-冷原子荧光法测定煤中痕量汞[J].光谱学与光谱分析,2004,24(9):1133-1135.
【2】朱莲珍.人和动物的微量元素营养[M].青岛:青岛出版社,1994.
【3】Kingston H M,Jassie L B.分析化学中的微波制样技术原理及应用[M].郭振库译.北京:中国气象出版社,1998.
【4】孙玉岭,刘景振.微波溶样在元素检测方面的应用研究[J].中国公共卫生,2002,18(2):231-232.
【5】郑用熙.分析化学中的数理统计方法[M].北京:科学出版社,1986.
【6】刘晶,郑楚光,徐杰英.微波消解-冷原子荧光法测定煤中痕量汞[J].光谱学与光谱分析,2004,24(9):1133-1135.
相关信息