Simultaneous Determination of Lead,Tin and Zinc in Tin-bronze by ICP-AES
摘 要
锡青铜试样溶于硝酸(1+1)溶液5 mL及盐酸(1+1)溶液3 mL中,所得试液于容量瓶中稀释至100 mL后供电感耦合等离子体原子发射光谱法(ICP-AES)分析,对光谱仪的工作条件及分析谱线的选择等分析条件作了试验并予以优化,测得铅、锡、锌三元素的检出限(3S)依次为0.069,0.091,0.088 mg·L-1.对方法的回收及精密度分别作了试验,测得其回收率在102.7%~103.3%之间,相对标准偏差(n=6)在0.7%~1.4%.
Abstract
Tin bronze sample was dissolved in a mixture of 5 mL of HNO3(1+1) and 3 mL of HCl(1+1),and the solution was diluted to 100 mL in volumetric flask,which was used for the ICP-AES analysis.Analytical conditions,including the working condition of the spectrograph,choice of analytical spectral lines and etc.,were tested and optimized.Values of detection limit (3S) of lead,tin and zinc were found to be 0.069,0.091 and 0.088 mg·L-1 respectively.Recovery and precision of the method were tested,giving values of recovery in the range from 102.7% to 103.3% and values of RSD′s (n=6) in the range of 0.7%-1.4%.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2007/6/21
修改稿日期
网络出版日期
作者单位点击查看
备注吴旭晖(1977-),女,漳洲人,助理工程师,从事化学分析及仪器分析工作.
引用该论文: WU Xu-hui. Simultaneous Determination of Lead,Tin and Zinc in Tin-bronze by ICP-AES[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2008, 44(12): 1223~1224
吴旭晖. 电感耦合等离子体原子发射光谱法同时测定锡青铜中铅、锡、锌[J]. 理化检验-化学分册, 2008, 44(12): 1223~1224
被引情况:
【1】黄慧萍,张萍,刘鹏程,韩鸿印,宋毅华, "电感耦合等离子体原子发射光谱法测定高纯氧化钇铕中13种杂质稀土元素",理化检验-化学分册 47, 213-215(2011)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】鞍钢钢铁研究所,沈阳钢铁研究所.实用冶金分析方法与基础[M].辽宁:辽宁科学技术出版社,1990:402-409.
【2】机械系统华东大区理化协作网.机械工厂实用化学分析[M].江苏:江苏省机械科学研究所,1985:285.
【3】机械工业部科技与质量监督司,中国机械工程学会理化检验分会.机械工程材料测试手册[M].辽宁:辽宁科学技术出版社,1996:103-105.
【2】机械系统华东大区理化协作网.机械工厂实用化学分析[M].江苏:江苏省机械科学研究所,1985:285.
【3】机械工业部科技与质量监督司,中国机械工程学会理化检验分会.机械工程材料测试手册[M].辽宁:辽宁科学技术出版社,1996:103-105.
相关信息