Single-sweeping Oscillopolarographic Determination of Ceftazidine in Injections
摘 要
提出了用单扫描示波极谱法测定药物中头孢他啶含量的方法.在0.10 mol·L-1硫酸底液中,头孢他啶在-0.96 V(vs.SCE)处有一灵敏的极谱还原峰,头孢他啶的质量浓度在8.0~2.0×103mg·L-1范围内与其峰电流呈线性关系,检出限(3S/b)为3.2 mg·L-1.用于头孢他啶针剂样品的分析,测得头孢他啶含量与高效液相色谱法所测得值一致.分析结果的相对标准偏差(n=6)在0.96%~1.31%之间,回收率在98.7%~102.0%之间.
Abstract
Single-sweeping oscillopolarography was applied to the determination of ceftazidine (CTZD) in its preparations.In a base solution of 0.10 mol·L-1 H2SO4,a sensitive polarographic reductive peak given by CTZD was observed at the potential -0.96 V (vs.SCE).Linear relationship between values of peak current (Ip) and concentration of CTZD was obtained in the range of 8.0-2.0×103mg·L-1.Detection limit (3S/b) of the method was found to be 3.2 mg·L-1.The proposed method was used in the determination of CTZD in samples of injections,giving results in conformity with the results found by HPLC.Values of RSD′s (n=6) and recovery found were in the ranges of 0.96%-1.31% and 98.7%-102.0% respectively.
中图分类号 O657.1
所属栏目 工作简报
基金项目 河南省教育厅自然科学基金资助项目(2008B150024),周口师范学院青年科研基金资助项目(zknuqn200826)
收稿日期 2008/1/2
修改稿日期
网络出版日期
作者单位点击查看
备注李艳霞(1973-),女,河南沈丘人,讲师,硕士,主要从事光电学研究.
引用该论文: LI Yan-xia,WANG Yun-sheng,LIU Bo. Single-sweeping Oscillopolarographic Determination of Ceftazidine in Injections[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2009, 45(1): 22~24
李艳霞,王运生,刘波. 单扫描示波极谱法测定针剂中头孢他啶含量[J]. 理化检验-化学分册, 2009, 45(1): 22~24
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】中华人民共和国卫生部药典委员会.中华人民共和国药典:二部[M].北京:化学工业出版社,2000:172.
【2】彭军,任耘,孙悦.高效液相色谱法测定头孢他啶注射剂的含量[J].中国医院药学杂志,2001,21(10):600-602.
【3】艾又生,徐楚鸿,陈华庭,等.高效液相色谱法测定血清中头孢他啶的浓度[J].华中科技大学学报:医学版,2004,33(4):512-514.
【4】郭丹,陈娜娜,杨西晓,等.高效毛细管电泳法测定注射用头孢他啶的含量[J].解放军药学学报,2004,20(4):310-312.
【5】李捷伟,柴逸锋,文长海.毛细管区带电泳法测定头孢他啶粉针剂的含量[J].西北药学杂志,2002,17(3):99-100.
【6】周杰,屈凌波,李建军,等.流动注射化学发光法测定头孢他啶粉针剂的含量[J].光谱实验室,2004,21(3):566-568.
【7】陈寿爱,李启隆.头孢氨苄的示波极谱研究[J].北京师范大学学报:自然科学版,1993,29(3):381-385.
【2】彭军,任耘,孙悦.高效液相色谱法测定头孢他啶注射剂的含量[J].中国医院药学杂志,2001,21(10):600-602.
【3】艾又生,徐楚鸿,陈华庭,等.高效液相色谱法测定血清中头孢他啶的浓度[J].华中科技大学学报:医学版,2004,33(4):512-514.
【4】郭丹,陈娜娜,杨西晓,等.高效毛细管电泳法测定注射用头孢他啶的含量[J].解放军药学学报,2004,20(4):310-312.
【5】李捷伟,柴逸锋,文长海.毛细管区带电泳法测定头孢他啶粉针剂的含量[J].西北药学杂志,2002,17(3):99-100.
【6】周杰,屈凌波,李建军,等.流动注射化学发光法测定头孢他啶粉针剂的含量[J].光谱实验室,2004,21(3):566-568.
【7】陈寿爱,李启隆.头孢氨苄的示波极谱研究[J].北京师范大学学报:自然科学版,1993,29(3):381-385.
相关信息