Simultaneous Spectrophotometric Determination of Iron Nickel Vanadium and Cobalt in Petroleum Products by Applying the Algorithm of Wavelet Transform and LSSVM
摘 要
石油产品样品经燃烧和灼烧除去碳氢化合物后,用稀盐酸溶解残渣,分取部分样品溶液用5-Br-PADAP作显色剂,对其中铁、镍、钒、钴的含量进行分光光度法同时测定.用试剂空白作参比溶液,在540~620 nm波长范围内每隔2 nm测定一次吸光度.所得数据用小波变换法处理以滤去分析信号中的噪声,然后用最小二乘支持向量机(LSSVM)算法解析所得分析数据.结果表明:LSSVM算法具有计算速度快,结果准确及泛化性能好等特点.用模拟样品对LSSVM算法进行预测,测得上述4元素的回收率在96.0%~103.5%之间.应用于分析实样时,所测得4元素结果与原子吸收光谱法的测得结果一致,所得结果的相对标准偏差(n=8)均小于4%.
Abstract
Sample of petroleum products was burned and ignited to eliminate hydrocarbons,and the residue was dissolved in dil.HCl.A aliquot of the sample solution was taken for simultaneous spectrophotometric determination of Fe3+,Ni2+,V(Ⅴ) and Co2+ with 5-Br-PADAP as color reagent.Values of absorbance were taken in the range of wavelengths between 540-620 nm at 2 nm intervals,using reagent blank as reference.Data of absorption spectra were treated by wavelet-transform to filter the noise from the analytical signals.The analytical data were then analyzed by the algorithm of least square support vector machine (LSSVM).As shown by the results,the algorithm of LSSVM showed its special features of speedy calculation,high accuracy and good generalization.In pretesting of LSSVM with some simulated samples,values of recovery for the 4 elements were found in the range of 96.0%-103.5%.In analysis of substantial samples,results obtained by this method were in conformity with those obtained by AAS.Values of RSD′s (n=8) for all the 4 elements were less than 4%.
中图分类号 O657
所属栏目 工作简报
基金项目 川北医学院青年基金(院基金-2004(理)-11)
收稿日期 2007/10/11
修改稿日期
网络出版日期
作者单位点击查看
备注申明金(1971-),男,四川南充人,硕士,讲师,主要从事化学计量学研究.
引用该论文: SHEN Ming-jin. Simultaneous Spectrophotometric Determination of Iron Nickel Vanadium and Cobalt in Petroleum Products by Applying the Algorithm of Wavelet Transform and LSSVM[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2009, 45(2): 210~212
申明金. 分光光度法同时测定石油制品中铁镍钒及钴的含量-小波变换-LSSVM算法的应用[J]. 理化检验-化学分册, 2009, 45(2): 210~212
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】Vapnik V N.Statistical learning theory[M].New York: John Wiley and Sons,1998:152.
【2】马晓国,余煜棉.用小波变换方法从强噪光谱中提取锑的弱信号[J].理化检验-化学分册,2002,38(12):605.
【3】陈莉莉,金继红,王红梅.小波变换-主成分回归分光光度法同时测定邻苯二酚、间苯二酚和对苯二酚三组分[J].分析科学学报,2004,20(1):57.
【4】姚肖刚,戴莲奎,方骏.基于支持向量机的柴油十六烷值近红外光谱测量方法[J].化工自动化及仪表,2004,31(2):48.
【5】李剑,陈德钊,成忠.构建支持向量机-偏最小二乘法为药物构效关系建模[J].分析化学,2006,34(2):263.
【6】马继平,吴海平,王兴宇,等.多波长线性回归分光光度法同时测定油中的铁、、钴、镍[J].光谱学与光谱分析,2000,20(1):122.
【2】马晓国,余煜棉.用小波变换方法从强噪光谱中提取锑的弱信号[J].理化检验-化学分册,2002,38(12):605.
【3】陈莉莉,金继红,王红梅.小波变换-主成分回归分光光度法同时测定邻苯二酚、间苯二酚和对苯二酚三组分[J].分析科学学报,2004,20(1):57.
【4】姚肖刚,戴莲奎,方骏.基于支持向量机的柴油十六烷值近红外光谱测量方法[J].化工自动化及仪表,2004,31(2):48.
【5】李剑,陈德钊,成忠.构建支持向量机-偏最小二乘法为药物构效关系建模[J].分析化学,2006,34(2):263.
【6】马继平,吴海平,王兴宇,等.多波长线性回归分光光度法同时测定油中的铁、、钴、镍[J].光谱学与光谱分析,2000,20(1):122.