FAAS Determination of Cadmium in Blood of White Mouse with Micro Sample Introduction
摘 要
离心分离小白鼠血液中的血红细胞和血清,所得的血红细胞经硝酸和过氧化氢消化处理.结合微量进样系统,进样量为300 μL,用火焰原子吸收光谱法测定了小白鼠血液中血红细胞和血清中镉的含量.镉的质量浓度在0.050~0.600 mg·L-1范围内与吸光度呈线性关系,检出限(3s/k)为2.2 μg·L-1.加标回收率为97.1%,相对标准偏差(n=6)为3.0%.应用此法测定了饮用0.1 g·L-1硝酸镉溶液15d的小白鼠的血清和血红细胞中镉的含量,试验组的血液中镉含量为对照组的7倍.
Abstract
The blood plasma and red blood cell in blood of white mouse were separated by centrifugation.The red blood cell was digested with HNO3 and H2O2.The content of Cd in blood plasma and red blood cell was determined by FAAS with micro-sample introduction system of 300 μL.Linear relationship between values of absorbance and mass concentration of Cd was obtained in the range of 0.050-0.600 mg·L-1,with detection limit (3s/k) of 2.2 μg·L-1.Value of recovery by standard addition method was found to be 97.1% with RSD′s (n=6) of 3.0%.The proposed method was used in the determination of Cd in blood plasma and red blood cell in blood samples of white mice which had been fed with 0.1 g·L-1 Cd(NO3)2 solution for 15 days,and the content of Cd of test group was 7 times higher than that of the control group.
中图分类号 O657.31
所属栏目 工作简报
基金项目 国家自然科学基金分析化学重点基金(20235010);国际合作基金(20611140646);中科院长春应化所电分析化学国家重点实验室基金;中科院研究生院院长基金项目资助;华北科技学院项目资助(2005-A-5).
收稿日期 2008/5/29
修改稿日期
网络出版日期
作者单位点击查看
备注马登军(1962-),男,河北省宣化人,教授,博士研究生,研究方向为痕量分析与生态环境.
引用该论文: MA Deng-jun,SUN Han-wen,FENG Hai-yan,LIU Song,MA Xiao-zhen,YUAN Zhuo-bin. FAAS Determination of Cadmium in Blood of White Mouse with Micro Sample Introduction[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2009, 45(6): 679~680
马登军,孙汉文,冯海燕,柳松,马晓珍,袁倬斌. 微量进样-火焰原子吸收光谱法测定小白鼠血液中镉[J]. 理化检验-化学分册, 2009, 45(6): 679~680
被引情况:
【1】龚倩,金高娃,李小蕾,史永富,蔡友琼,顾润润, "电感耦合等离子体质谱法测定海洋贝类中镉、铬、铜和铅",理化检验-化学分册 48, 594-596(2012)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】刘杰.镉的毒性和毒理学研究进展[J].中华劳动卫生职业病杂志,1998,16(1):2-4.
【2】TSANGARIS G T,TZORTZATOU-STATHOPULOU F.Cadmium induces apoptosis differentially on immune system cell lines[J].Toxicology,1998,128:143-150.
【3】王文仲,徐兆发,杨敬华,等.镉对小鼠肾脏细胞凋亡的影响[J].中国工业医学杂志,2004,17(1):4-6.
【4】赵伟,王强.镉对小鼠心肌细胞和肝细胞DNA的损伤[J].环境与职业医学,2005,22(6):523-524.
【5】阎正,蒋守规.微量注射进样火焰原子吸收法测定耳血全血锌、铜及幼儿正常参考值的获得[J].光谱学与光谱分析,1993,13(2):71-72.
【6】师长宏,高双斌,龚出明.脉冲进样火焰原子吸收光谱法测定血清中结合态和非结合态锌[J].理化检验-化学分册,1995,31(1):41-43.
【7】郝爱国,张莹,佟淑娟,等.微量进样火焰原子吸收光谱法测定血浆、红细胞中铜、铁和锌[J].光谱实验室,1997,14(3):41-44.
【8】孙建民,杨莉丽,张德强,等.微量注射进样火焰原子吸收法测量植物油中锌[J].光谱学与光谱分析,1999,19(3):404-405.
【9】钱小妹,周伶,丁建森.微量进样火焰原子光谱法测定血样中的铜和锰[J].江苏预防医学,2003,14(1):59-60.
【2】TSANGARIS G T,TZORTZATOU-STATHOPULOU F.Cadmium induces apoptosis differentially on immune system cell lines[J].Toxicology,1998,128:143-150.
【3】王文仲,徐兆发,杨敬华,等.镉对小鼠肾脏细胞凋亡的影响[J].中国工业医学杂志,2004,17(1):4-6.
【4】赵伟,王强.镉对小鼠心肌细胞和肝细胞DNA的损伤[J].环境与职业医学,2005,22(6):523-524.
【5】阎正,蒋守规.微量注射进样火焰原子吸收法测定耳血全血锌、铜及幼儿正常参考值的获得[J].光谱学与光谱分析,1993,13(2):71-72.
【6】师长宏,高双斌,龚出明.脉冲进样火焰原子吸收光谱法测定血清中结合态和非结合态锌[J].理化检验-化学分册,1995,31(1):41-43.
【7】郝爱国,张莹,佟淑娟,等.微量进样火焰原子吸收光谱法测定血浆、红细胞中铜、铁和锌[J].光谱实验室,1997,14(3):41-44.
【8】孙建民,杨莉丽,张德强,等.微量注射进样火焰原子吸收法测量植物油中锌[J].光谱学与光谱分析,1999,19(3):404-405.
【9】钱小妹,周伶,丁建森.微量进样火焰原子光谱法测定血样中的铜和锰[J].江苏预防医学,2003,14(1):59-60.
相关信息