SPME-GC-MS Determination of Trace Amount of Tetramine in Blood
摘 要
血样中的毒鼠强用固相微萃取法分离.取2 mL血样加水稀释至15 mL,插入聚丙烯酸酯萃取纤维头30 min,取出萃取头用水洗提2~3次后,在仪器的前进样口加热除去残留的水分,然后将萃取头插入仪器的进样口进行热解吸,并测定其含量.此方法的检出限(3S/N)为1.1 μg·L-1.在毒鼠强质量浓度为100 μg·L-1的水平上测定了方法的相对标准偏差(n=6)为4.03%.
Abstract
Tetramine was separated from the blood sample (2 mL of blood diluted to 15 mL with water) by SPME with polyacrylic fiber extractor (PA extractor).After dipping the PA extractor into the sample solution for 30 min,it was taken out,washed 2-3 times with water,and heated to remove any adhered water.The extractor was then inserted into the smaple inlet of the instrment,and tetramine on the extractor was thermally desorbed and determined by GC-MS.Detection limit (3S/N) of the method found was 1.1 μg·L-1.Value of RSD (n=6) found at concentration level of 100 μg·L-1 was 4.03%.
中图分类号 O657.6
所属栏目 工作简报
基金项目
收稿日期 2008/3/8
修改稿日期
网络出版日期
作者单位点击查看
备注赵舰(1967-),男,重庆大足人,副主任技师,主要研究方向为食品卫生检验.
引用该论文: ZHAO Jing,GU Wan-jiang,ZHOU Qian-ru,ZHANG Xue-kui. SPME-GC-MS Determination of Trace Amount of Tetramine in Blood[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2009, 45(6): 729~731
赵舰,顾万江,周倩如,张学煃. 固相微萃取-气相色谱-质谱法测定血中痕量毒鼠强[J]. 理化检验-化学分册, 2009, 45(6): 729~731
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王劲,徐伯洪.毒鼠强中毒检验检测方法的研究进展[J].中国医学检验杂志,2005,6(1):80.
【2】刘俊亭.毒鼠强化学结构以及命名中的几个问题[J].卫生研究,2006,35(2):129-130.
【3】徐溢,付钰洁.固相微萃取头制备技术及试验方法的进展[J].色谱,2004,22(5):528-534.
【4】张金艳,叶非.新型无溶剂样品制备方法[J].理化检验-化学分册,2001,37(5):236-239.
【5】张新威.中国刑事科学技术大全毒品和毒物检验[M].北京:中国人民公安大学出版社,2003:626.
【2】刘俊亭.毒鼠强化学结构以及命名中的几个问题[J].卫生研究,2006,35(2):129-130.
【3】徐溢,付钰洁.固相微萃取头制备技术及试验方法的进展[J].色谱,2004,22(5):528-534.
【4】张金艳,叶非.新型无溶剂样品制备方法[J].理化检验-化学分册,2001,37(5):236-239.
【5】张新威.中国刑事科学技术大全毒品和毒物检验[M].北京:中国人民公安大学出版社,2003:626.
相关信息