ICP-AES Determination of Calcium Iron Nickel Vanadium in Petrol Coke
摘 要
石油焦样品经硝酸-高氯酸混合溶液湿法消解后,采用电感耦合等离子体原子发射光谱法测定其中的钙、铁、镍和钒的含量.选择波长为396.847,238.204,231.604,309.310 nm的4条谱线依次作为测定钙、铁、镍和钒测定结果的分析线.钙、铁、镍和钒的相对标准偏差(n=6)在1.4%~3.0%之间,检出限(3δ)均小于0.040 mg·L-1.应用此法测定石油焦样品中4种元素的含量,加标回收率在96.2%~102.4%之间,与原子吸收光谱法相比,两种方法所得结果相一致.
Abstract
The petrol coke sample was digested with mixed solution of HNO3-HClO4,and the amounts of Ca,Fe,Ni,V in sample solution were determined by ICP-AES.Wavelengths of 396.847,238.204,231.604 and 309.310 nm were selected as analytical lines for the determination of Ca,Fe,Ni and V,respectively.Values of RSD′s (n=6) for Ca,Fe,Ni and V were in the range of 1.4%-3.0%,and detection limits (3δ) found were less than 0.040 mg·L-1.The proposed method was used in the determination of the 4 elements in petrol coke,giving values of recovery in the range 96.2%-102.4%.The results obtained was in conformity with those obtained by AAS.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2008/2/4
修改稿日期
网络出版日期
作者单位点击查看
备注宋吉利(1961-),男,山东乳山人,学士,高级工程师,主要从事理化检验和仪器分析工作.
引用该论文: SONG Ji-li,WEI Xiao-hong,YIN Gang. ICP-AES Determination of Calcium Iron Nickel Vanadium in Petrol Coke[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2009, 45(8): 905~906
宋吉利,卫晓红,殷刚. 电感耦合等离子体原子发射光谱法测定石油焦中钙、铁、镍和钒[J]. 理化检验-化学分册, 2009, 45(8): 905~906