FI-Amperometric Determination of Traces of Nitrite with Glassy Carbon Electrode Modified by Poly-Neutral Red Film
摘 要
在由pH 6.0磷酸盐缓冲溶液,0.5 mol·L-1硝酸钠及1.0×10-4mol·L-1中性红溶液组成的电解质溶液中,用循环伏安法以50 mV·s-1扫描速率在玻碳电极上先后在电位-1.3~1.9 V及-0.7~0.9 V范围内扫描6周及15周,从而制得聚中性红(PNR)膜修饰的玻碳电极.在此修饰电极上,亚硝酸根在电位0.872 V(vs.Ag/AgCl)处出现明显的氧化峰.据此并结合流动注射技术提出了安培法测定亚硝酸根的快速方法.方法的工作条件为① 采样环体积20 μL;② 载流0.025 mol·L-1磷酸盐缓冲溶液(pH 7.0)及0.5 mol·L-1氯化钾溶液;③ 载流流量1.8 mL·min-1;④ 工作电位0.95 V(vs.Ag/AgCl).峰电位值与亚硝酸根浓度在0.8~100 μmol·L-1间呈线性关系,其检出限(3σ)为1.0×10-7mol·L-1.以浓度为4.0×10-6mol·L-1亚硝酸根标准溶液平行测定8次,测得其相对标准偏差为3.6%.用此修饰电极连续检测24h,其电流信号保持稳定.此方法应用于分析火腿肠及自来水、湖水等样品,所得回收率在93.0%~112.0%之间.
Abstract
Poly neutral red (PNR) film modified GCE was prepared by cyclic voltammetry (CV) with scanning rate of 50 mV·s-1 in an electrolyte containing PBS of pH 6.0,0.5 mol·L-1 NaNO3 and 1.0×10-4mol·L-1 neutral red solution for 6 cycles at -1.3-1.9 V (vs.Ag/AgCl) and 15 cycles at -0.7-0.9 V.A significant oxidation peak of nitrite ion was observed at the potential of 0.872 V at the PNR modified electrode.By using flow injection technique,a rapid method of amperometric determination nitrite was proposed with the following working parameters: ① vol.of sampling ring 20 μL;② carrying solution 0.025 mol·L-1 PBS (pH 7.0)+0.5 mol·L-1 KCl solution;③ flow rate of the carrier 1.8 mL·min-1;④ working potential 0.95 V (vs.Ag/AgCl).Linear relationship between values of peak current and concentration of nitrite was obtained in the range of 0.8-100 μmol·L-1,with detection limit (3σ) of 1.0×10-7mol·L-1.Eight replicate determinations of NO-2 standard solution of 4.0×10-6mol·L-1 were carried out by the proposed method,giving RSD of 3.6%,and the current signals were kept stable for 24 h in continuous operation with the modified electrode.In applying this method to the analysis of samples of ham sausages and water,values of recovery found were in the range of 93.0%-112.0%.
中图分类号 O657.1
所属栏目 工作简报
基金项目
收稿日期 2009/1/2
修改稿日期
网络出版日期
作者单位点击查看
备注吴慧庆(1986-),女,安徽人,硕士,主要研究流动注射与电化学分析.
引用该论文: WU Hui-qing,SU Yao-dong,WANG Min. FI-Amperometric Determination of Traces of Nitrite with Glassy Carbon Electrode Modified by Poly-Neutral Red Film[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2010, 46(3): 232~234
吴慧庆,苏耀东,王敏. 流动注射-聚中性红膜修饰电极安培法测定痕量亚硝酸根[J]. 理化检验-化学分册, 2010, 46(3): 232~234
被引情况:
【1】顾玲,张苗,贺亚梅, "聚硫堇修饰碳糊电极差分脉冲伏安法测定依诺沙星",理化检验-化学分册 49, 420-424(2013)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】傅厚暾,赵俐敏,李贝,等.氧化银沉淀-离子色谱法测定海水中的痕量亚硝酸根和硝酸根[J].色谱,2007,25(1):120-123.
【2】翟继英.催化荧光光度法测定痕量亚硝酸根[J].理化检验-化学分册,2006,42(8):670-671.
【3】AFKHAMI A,BAHRAM M,GHOLAMI S,et al.Micell-mediated extraction for the spectrophotometric determination of nitrite in water and biological samples based on its reaction with p-nitroaniline in the presence of diphenylamine[J].Analytical Biochemistry,2005,336:295-299.
【4】王立霞,王瑜.痕量亚硝酸根的光度测定-基于亚硝酸根对溴酸钾氧化甲酚红的催化作用[J].理化检验-化学分册,2007,43(8):658-662.
【5】李梦瑶,孔令蜜,朱佩思,等.细胞色素C/L-半胱氨酸修饰金电极检测亚硝酸根[J].理化检验-化学分册,2008,44(6):495-498.
【6】PEI Jian-hong,LI Xiao-yuan.Electrochemical study and flow-injection amperometric detection of NO-2 at CuPtCl6 chemically modified electrode[J].Talanta,2000,51:1107-1115.
【7】孙元喜,冶保献,周性尧.聚中性红膜修饰电极的电化学特性及其电催化性能[J].分析化学,1998,26(2):166-169.
【8】王亚珍,邱红心.亚硝酸根离子在聚中性红膜修饰玻碳电极上的电化学行为[J].分析仪器,2008,4:23-27.
【2】翟继英.催化荧光光度法测定痕量亚硝酸根[J].理化检验-化学分册,2006,42(8):670-671.
【3】AFKHAMI A,BAHRAM M,GHOLAMI S,et al.Micell-mediated extraction for the spectrophotometric determination of nitrite in water and biological samples based on its reaction with p-nitroaniline in the presence of diphenylamine[J].Analytical Biochemistry,2005,336:295-299.
【4】王立霞,王瑜.痕量亚硝酸根的光度测定-基于亚硝酸根对溴酸钾氧化甲酚红的催化作用[J].理化检验-化学分册,2007,43(8):658-662.
【5】李梦瑶,孔令蜜,朱佩思,等.细胞色素C/L-半胱氨酸修饰金电极检测亚硝酸根[J].理化检验-化学分册,2008,44(6):495-498.
【6】PEI Jian-hong,LI Xiao-yuan.Electrochemical study and flow-injection amperometric detection of NO-2 at CuPtCl6 chemically modified electrode[J].Talanta,2000,51:1107-1115.
【7】孙元喜,冶保献,周性尧.聚中性红膜修饰电极的电化学特性及其电催化性能[J].分析化学,1998,26(2):166-169.
【8】王亚珍,邱红心.亚硝酸根离子在聚中性红膜修饰玻碳电极上的电化学行为[J].分析仪器,2008,4:23-27.
相关信息