HG-CV-AFS Determination of Mercury in Copper Concentrates
摘 要
用氢化物发生-冷原子荧光光谱法测定铜精矿中汞的含量.考察了仪器的工作条件原子化温度、原子化器高度、灯电流、负高压、载气和屏蔽气流量对测定的影响.采用主量元素匹配法消除基体干扰,优化了反应体系的介质与酸度、还原剂的浓度等条件.荧光强度与汞的质量浓度在2.0 μg·L-1以内呈线性关系,检出限(3s/k)为0.010 8 μg·L-1,相对标准偏差(n=11)小于2%.此法用于铜精矿样品中汞含量的测定,加标回收率为92.0%~111.7%.
Abstract
A method for the determination of mercury in copper concentrates by HG-CV-AFS was proposed.Working conditions of the instrument,including atomization temperature,height of atomizer,negative high voltage,lamp current,the rates of carrier and shielding gas,were studied.Influential factors,including kinds and concentration of acids and concentration of reducing agent were optimized.The matrix interference was eliminated by the matrix matching method.Linear relationship between the fluorescence intensity and mass concentration of Hg was found in the range within 2.0 μg·L-1,with detection limit (3s/k) of 0.010 8 μg·L-1.Values of RSD (n=11) of the method found was less than 2%.The proposed method was applied to the determination of mercury in samples of copper concentrate,and test for recovery was made by standard addition method,giving values of recovery in the range of 92.0%-111.7%.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2008/12/9
修改稿日期
网络出版日期
作者单位点击查看
备注吕晓华(1975-),女,工程师,硕士,主要从事进出口化工矿产、金属材料的检测及分析方法的研究工作.
引用该论文: Lv Xiao-hua,SONG Wu-yuan. HG-CV-AFS Determination of Mercury in Copper Concentrates[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2010, 46(3): 244~245
吕晓华,宋武元. 氢化物发生-冷原子荧光光谱法测定铜精矿中汞[J]. 理化检验-化学分册, 2010, 46(3): 244~245
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】张道礼,严少仪,魏伟.冷蒸气原子吸收光谱法测定铜精矿中的汞[J].光谱实验室,1993,10(5):52-56.
【2】宋国玺.冷原子吸收法测定锌精矿中的汞[J].分析测试技术与仪器,2000,6(4):239-241.
【3】蔡泓,冯俊汉,庄军,等.冷原子吸收分光光度法快速测定锌精矿和铅精矿中汞的探讨[J].检验检疫科学,1997,7(2):24-25.
【4】姜丽民.冷原子吸收光度法测定出口锌精矿中汞[J].理化检验-化学分册,1999,35(12):565-566.
【5】马红岩.ICP-AES法测定进口铜精矿中有害元素[J].理化检验-化学分册,2004,40(6):334-340.
【6】杨莉丽,李娜,张德强,等.氢化物发生-双道原子荧光光谱法在我国的应用研究进展[J].光谱实验室,2004,21(1):102-105.
【7】刘彻,满瑞林.原子荧光光谱法测定铅锌精矿中汞的研究[J].浙江冶金,2003(3):29-31.
【8】YS/T 461.6-2003混合铅锌精矿化学分析方法汞的测定冷原子荧光光谱法[S].
【9】张锂,韩国才.原子荧光光谱法测定汞、铅、锑的研究[J].西安工程科技学院学报,2007,21(3):385-389.
【10】杨理勤,李玄辉.金对原子荧光法测汞化学干扰机理的实验研究[J].现代科学仪器,2006(4):81-82.
【2】宋国玺.冷原子吸收法测定锌精矿中的汞[J].分析测试技术与仪器,2000,6(4):239-241.
【3】蔡泓,冯俊汉,庄军,等.冷原子吸收分光光度法快速测定锌精矿和铅精矿中汞的探讨[J].检验检疫科学,1997,7(2):24-25.
【4】姜丽民.冷原子吸收光度法测定出口锌精矿中汞[J].理化检验-化学分册,1999,35(12):565-566.
【5】马红岩.ICP-AES法测定进口铜精矿中有害元素[J].理化检验-化学分册,2004,40(6):334-340.
【6】杨莉丽,李娜,张德强,等.氢化物发生-双道原子荧光光谱法在我国的应用研究进展[J].光谱实验室,2004,21(1):102-105.
【7】刘彻,满瑞林.原子荧光光谱法测定铅锌精矿中汞的研究[J].浙江冶金,2003(3):29-31.
【8】YS/T 461.6-2003混合铅锌精矿化学分析方法汞的测定冷原子荧光光谱法[S].
【9】张锂,韩国才.原子荧光光谱法测定汞、铅、锑的研究[J].西安工程科技学院学报,2007,21(3):385-389.
【10】杨理勤,李玄辉.金对原子荧光法测汞化学干扰机理的实验研究[J].现代科学仪器,2006(4):81-82.
相关信息