加压毛细管电色谱法分离美西律对映体
          
Resolution of Enantiomer of Mexiletine by Pressurized Capillary Electrochromatography

摘    要
采用加压毛细管电色谱法,以羟丙基-β-环糊精作为手性选择剂,对美西律对映体进行手性分离.在优化的试验条件下,16 g·L-1羟丙基-β-环糊精为手性选择剂,pH 2.5的乙腈与10 mmol·L-1磷酸盐缓冲溶液以体积比1比1混合溶液为流动相,运行电压10 kV,毛细管柱温20 ℃,美西律对映体在4 min内成功分离,分离度为1.51.
标    签 加压毛细管电色谱   盐酸美西律   对映体拆分   羟丙基-β-环糊精   Pressurized capillary electrochromatography   Mexiletine hydrochloride   Resolution of enantiomers   Hydroxypropyl -β-cyclodextrin  
 
Abstract
A method of pressurized capillary electrochromatography was proposed for the resolution of enantiomers of mexiletine using hydroxypropyl-β-cyclodextrin (16 g·L-1) as selective chiral agent.A mixed solution of acetonitrile and 10 mmol·L-1 phosphate buffer solution(1+1 by vol.) of pH 2.5 was used as mobile phase.The separation voltage of 10 kV and temperature of capillary column of 20 ℃ were chosen.Under the optimized conditions,the enantiomer of mexiletine was successfully separated within 4 min with resolution factor of 1.51.

中图分类号 O652.63

 
  中国光学期刊网论文下载说明


所属栏目 工作简报

基金项目

收稿日期 2009/1/26

修改稿日期

网络出版日期

作者单位点击查看

备注李英杰(1961-),男,黑龙江人,教授,主要从事电泳、电色谱分析研究工作.

引用该论文: LI Ying-jie,SUN Peng,GAO Yu-lin,GAO Li-di. Resolution of Enantiomer of Mexiletine by Pressurized Capillary Electrochromatography[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2010, 46(4): 441~442
李英杰,孙鹏,高玉玲,高立娣. 加压毛细管电色谱法分离美西律对映体[J]. 理化检验-化学分册, 2010, 46(4): 441~442


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】LANCHOTE V I,BONATO P S.High-perfomance liquid chromatographic detemination of mexiletine enantiomers in plasma using direct and indirect enantioselective eparations[J].J Chrarnatogr B,1996,685:281-289.
 
【2】MEHVAR R,BROCKS D R,VAKILY M.Impact of stereoselectivity on the phamracokinetics and phamracodynamics of antiarrhythmic drugs[J].Clin Phannacokinet,2002,41(8):533-558.
 
【3】康经武,阮宗琴,欧庆瑜,等.盐酸美西律对映体的毛细管电泳分离[J].分析化学,1997,25(3):290-293.
 
【4】曹枫,张维冰,阎超,等.压力对加压电色谱分离选择性影响的研究[J].分析化学,2004,32(2):143-147.
 
【5】STRICKMANN B C,GOTTFRIED B,CLAUDIA D,et al.Separation and identification of etodolac and its urinary phase Ⅰ metabolites using capillary electrochromatography and on-line capillary electrochromatography-electrospray ionisation mass spectrometry coupling[J].J Chromatogr A,2000,887(1/2):393-407.
 
【6】RU Qin-hua,LUO Guo-an,FU Yu-rong.Effect of various modes of pressurization on the separation in capillary electrochromatography[J].J Chromatogr A,2001,924(1/2):331-336.
 
【7】GERALD G,MARTIN G S.Chiral separation by capillary electromigration techniques[J].J Chromatogr A,2008,1204(2):140-156.
 
【8】JOSEPH J P,MARA T M,DIPTI S.Capillary liquid chromatography and capillary electrochromatography using silica hydride stationary phases[J].J Chromatogr A,2008,1191(1/2):136-140.
 
【9】王志,孙亦梁,孙曾培.高效毛细管电泳分离手性物质[J].分析测试学报,1996,15(2):85-92.
 
相关信息
   标题 相关频次
 加压毛细管电色谱法分离盐酸奥昔布宁对映体
 6
 高效毛细管电泳法分离1-甲基-3-苯基丙胺对映体
 5
 手性整体柱毛细管电色谱法拆分溴氰菊酯对映体
 4
 羧甲基聚合-β-环糊精作为选择剂应用于毛细管电泳法拆分手性化合物
 4
 高效液相色谱流动相手性添加剂法拆分氯苯甘醚对映体
 3
 手性流动相添加剂-超高效液相色谱法拆分头孢噻吩对映体
 3
 电感耦合等离子体原子发射光谱法测定铝锰铁中硅和磷
 2
 高能球磨与热压烧结制备TiAl基合金
 2
 高效液相色谱手性流动相添加剂法拆分头孢羟氨苄对映体
 2
 静态顶空气相色谱法测定涂料与胶粘剂中的苯系物
 2
 立方氮化硼-碳化钨-钴复合材料制备工艺的改进
 2
 铝合金表面锡盐转化膜的制备及其耐蚀性
 2
 洛美沙星对映体在Chiralcel OJ柱上的拆分机理
 2
 镁合金表面的搅拌摩擦加工改性
 2
 汽车冲压外覆盖件高点高度影响因素及控制阈值
 2
 湿法超声机械镀锌层的结构分析
 2
 羧基丁二酰-β-环糊精微球毛细管柱的制备及其应用于气相色谱
 2
 羧甲基-β-环糊精/SiO2/TiO2毛细管开管柱的制备及其应用于毛细管电色谱
 2
 微波消解样品-原子荧光光谱法测定酸菜中砷
 2
 阳极氧化铝模板合成介孔ZrO2纳米线及其光致发光性能
 2
 荧光分光光度法测定痕量铜-基于铜(Ⅱ)水杨基荧光酮-乳化剂OP-β-环糊精荧光熄灭反应体系
 2
 闸门受蚀构件的力学性能衰减特性
 2
 浊点萃取-火焰原子吸收光谱法测定怀药中微量铁
 2
 Al-CAS-β-CD-CTMAB四元络合体系光度法测定水中微量铝
 1
 高效毛细管电泳法分离氟卡尼对映体
 1
 高效液相色谱-手性流动相添加法拆分高精氨酸对映体
 1
 高效液相色谱-手性流动相添加法拆分盐酸丙胺卡因对映体
 1
 工业CT技术在弹药装药密度差测量中的应用
 1
 户内燃气立管的腐蚀与防护
 1
 上海铁路南站大型钢结构工程的涂装防护
 1