HG-AFS Determination of Arsenic in Iron Ore with Microwave Assisted Sample Digestion
摘 要
应用氢化物发生-原子荧光光谱法测定了铁矿石中微量砷.试样用硝酸、盐酸及氟氢酸的混合酸在微波消解仪中消解处理.经试验选定微波消解程序为:① 消解功率650 V;② 以5 ℃·min-1速率升温至170 ℃,保持20 min;③ 冷却20 min,在所得溶液中加入饱和硼酸溶液使游离氢氟酸络合,再加入硫脲及抗坏血酸溶液作掩蔽剂后定容为50 mL,在仪器工作条件下进行砷的测定.设置样品溶液的进样量为1.0 mL,10 g·L-1硼氢化钾溶液的加入量为0.5 mL.在制作标准曲线时加入一定量的铁以抵消基体铁的干扰.砷的质量浓度在0.90~100 μg·L-1范围内与相应的荧光强度之间呈线性关系.方法的检出限(3s)为0.40 μg·L-1.按所提出的方法测定了铁矿石标准样品中砷量,所得结果与认定值相符.
Abstract
HG-AFS was applied to the determination of arsenic in iron ore.The sample was digested in a microwave sample digestor under the optimized conditions of: ① power for digestion: 650 V;② raising the digestion temperature to 170 ℃ at a rate of 5 ℃·min-1,and keeping for 20 min;and ③ cooling for 20 min.Definite amounts of sat′d boric acid solution and solutions of thiourea and ascorbic acid were added to the sample solution as complexing agents.The sample solution was diluted to 50 mL and used for HG-AFS determination of arsenic under the working condition of the instrument.The preset volumes of injection of sample solution and 10 g·L-1 KBH4 solution were 1.0 mL and 0.5 mL respectively.Definite amount of iron solutions were added to each of the test solutions in the preparation of standard curve in order to match the matrix inteference of iron.Linear relationship between values of fluorescence intensity and mass concentration of arsenic was obtained in the range from 0.90 to 100 μg·L-1,and detection limit (3s) found for the method was 0.40 μg·L-1.The proposed method was applied to the determination of arsenic in standard samples of iron ore,giving results in consistency with the standard values.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2009/6/2
修改稿日期
网络出版日期
作者单位点击查看
备注武素茹(1982-),女,山西忻州人,硕士,主要从事矿产品相关项目检测.
引用该论文: WU Su-ru,GU Song-hai,YAO Chuan-gang,WANG Hong,MA De-qi,SU Ming-yue. HG-AFS Determination of Arsenic in Iron Ore with Microwave Assisted Sample Digestion[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2010, 46(9): 1043~1045
武素茹,谷松海,姚传刚,王虹,马德起,苏明跃. 微波消解试样-氢化物发生-原子荧光光谱法测定铁矿石中砷[J]. 理化检验-化学分册, 2010, 46(9): 1043~1045
被引情况:
【1】闵红,朱志秀,秦晔琼,刘曙,周海明, "铁矿石中砷含量的测定方法研究进展",理化检验-化学分册 52, 741-744(2016)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王松青,应海松.铁矿石与钢材的质量检验[M].北京:冶金工业出版社,2007:50-55.
【2】王建琴,梁云生.示波极谱法测定铁矿石中微量砷[J].岩矿测试,2002,21(3):236-238.
【3】周耀明,余江,于磊,等.ICP-AES测定高砷铁矿中砷和钒[J].光谱实验室,2007,24(5):829-831.
【4】李波,崔杰华,刘东波,等.微波消解-氢化物发生原子荧光法同时测定土壤中的砷汞[J].分析试验室,2008,27(7):106-108.
【5】张锂,韩国才.增压微波消解-氢化物-原子荧光光谱法测定铁矿石中的砷[J].矿物岩石,2006,21(1):98-100.
【6】周永义,谷学新,范国强.微波消解技术及其在分析化学中的应用[J].冶金分析,2004,24(2):30-36.
【7】吴政宙,张军华.微波消解技术在铁矿石分析中的应用研究[J].冶金分析,2005,25(5):69-70.
【2】王建琴,梁云生.示波极谱法测定铁矿石中微量砷[J].岩矿测试,2002,21(3):236-238.
【3】周耀明,余江,于磊,等.ICP-AES测定高砷铁矿中砷和钒[J].光谱实验室,2007,24(5):829-831.
【4】李波,崔杰华,刘东波,等.微波消解-氢化物发生原子荧光法同时测定土壤中的砷汞[J].分析试验室,2008,27(7):106-108.
【5】张锂,韩国才.增压微波消解-氢化物-原子荧光光谱法测定铁矿石中的砷[J].矿物岩石,2006,21(1):98-100.
【6】周永义,谷学新,范国强.微波消解技术及其在分析化学中的应用[J].冶金分析,2004,24(2):30-36.
【7】吴政宙,张军华.微波消解技术在铁矿石分析中的应用研究[J].冶金分析,2005,25(5):69-70.