Application of Current Requirement Test to Mitigation of DC Transit Stray Current Interference
摘 要
埋地钢质管道受地铁动态直流杂散电流干扰的缓解是管道界的一个难题。本工作尝试使用强制电流阴极保护的方式, 用强化的阴极保护电流缓解地铁动态干扰对管道的腐蚀影响。馈电试验有助于选取合适的强制电流阳极地床位置以及强制电流阴极保护系统的输出, 取得最优的排流效果。
Abstract
Mitigation of DC transit stray current interference is one of the challenges faced by pipeline industry. In this study impressed current cathoclic protection (ICCP) was tried to mitigate the DC interference from DC transit system, using enhanced CP current as a counteract measure to prevent corrosion. Current requirement test is an optimal method to choose the anode site and output parameters for ICCP system to get an optimized mitigation result.
中图分类号 TG174.4 DOI 10.11973/fsyfh-201511019
所属栏目 应用技术
基金项目
收稿日期 2015/8/13
修改稿日期
网络出版日期
作者单位点击查看
备注韩非(1981-),工程师,从事燃气管道运行管理工作,
引用该论文: HAN Fei. Application of Current Requirement Test to Mitigation of DC Transit Stray Current Interference[J]. Corrosion & Protection, 2015, 36(11): 1101
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】陈飞, 周吉祥, 牟南翔. 埋地管道直流杂散电流排除实践[J]. 腐蚀与防护, 2013,34(2):171-173.
【2】NACE InternationalCP Interference training material[M]. Atlanta:January NACE International,2008.
【3】GB 21448-2008埋地钢质管道阴极保护技术规范[S].
【4】AS2832.1-2004Cathodic protection of metals part1:pipes and cables[S].
【2】NACE InternationalCP Interference training material[M]. Atlanta:January NACE International,2008.
【3】GB 21448-2008埋地钢质管道阴极保护技术规范[S].
【4】AS2832.1-2004Cathodic protection of metals part1:pipes and cables[S].
相关信息