Influence of Displacement Blocking of Constant Force Hanger on Pipeline Force
摘 要
某高压主蒸汽管道一组恒力吊架的位移指针与锁定装置发生卡碰现象,导致管道热位移受阻。针对该现象,通过静力计算,定量地分析了其对管系应力及高压缸端口推力和力矩的影响。结果表明: 当恒力吊架位移受阻时,管道系统对高压缸的推力和力矩变化较大,管道系统的最大二次应力也相应增加。
Abstract
The displacement pointer of the constant force hanger of a high-pressure main steam pipeline was stuck with locking device which resulted in the thermal displacement blocking of the pipeline. Regarding such situation, the influence of the thermal displacement blocking on pipeline force, high-pressure cylinder force and torque was quantitatively analyzed by static calculation. The results show that when the displacement of constant force hanger was blocked, high-pressure cylinder’s force and torque coming from the pipeline changed greatly, and the maximum secondary stress of the pipeline increased accordingly.
中图分类号 TB12 DOI 10.11973/lhjy-wl201511003
所属栏目 试验与研究
基金项目
收稿日期 2015/7/24
修改稿日期
网络出版日期
作者单位点击查看
备注张少斌(1968-),男,工程师,学士。
引用该论文: ZHANG Shao-bin,LEI Ling-bo,AN Fu-li,LIU Bin. Influence of Displacement Blocking of Constant Force Hanger on Pipeline Force[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2015, 51(11): 766~768
张少斌,雷凌波,安付立,刘宾. 恒力吊架位移受阻对管系受力的影响[J]. 理化检验-物理分册, 2015, 51(11): 766~768
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】DL/T 5366-2014火力发电厂汽水管道应力计算技术规程[S].
【2】DL/T 616-2014火力发电厂汽水管道与支吊架维修调整导则[S].
【3】DL/T 5054-1996火力发电厂汽水管道设计技术规定[S].
【4】刘宾,王军民,安付立,等.恒力吊架力学性能对低温再热蒸汽管道热位移的影响[J].理化检验物理分册,2013,49(4):244-246.
【5】曹建军,安付立,刘宾.某330 MW流化床锅炉屏过出口集箱连接管放气管道开裂原因分析与处理措施[J].理化检验物理分册,2012,48(12):831-833.
【2】DL/T 616-2014火力发电厂汽水管道与支吊架维修调整导则[S].
【3】DL/T 5054-1996火力发电厂汽水管道设计技术规定[S].
【4】刘宾,王军民,安付立,等.恒力吊架力学性能对低温再热蒸汽管道热位移的影响[J].理化检验物理分册,2013,49(4):244-246.
【5】曹建军,安付立,刘宾.某330 MW流化床锅炉屏过出口集箱连接管放气管道开裂原因分析与处理措施[J].理化检验物理分册,2012,48(12):831-833.