GC-MS Determination of Polychlorinated Biphenyls in Polymer Materials Used in Electrical and Electronic Products
摘 要
采用气相色谱-质谱法测定电子电气产品聚合物材料中的多氯联苯(PCBs)。采用丙酮-正己烷(1+1)混合溶剂对样品进行超声萃取,萃取液经中性硅胶固相萃取柱净化后,在DB-5MS UI毛细管柱上分离,质谱中选择电子轰击离子源和选择离子监测模式。一氯至十氯PCBs的线性范围均为0.1~10 mg·L-1,测定下限(10S/N)均为0.1 mg·kg-1。加标回收率在86.0%~109%之间,测定值的相对标准偏差(n=7)不大于10%。
Abstract
GC-MS was applied to the determination of polychlorinated biphenyls in polymer materials used in electrical and electronic products. The sample was extracted ultrasonically with a mixture of acetone and n-hexane (1+1). The extract was purified with a solid phase extraction column filled with neutral sllica gel and then separated on a DB-5MS UI capillary column. EI and SIM were adopted in MS. The linearity ranges of polychlorinated biphenyls (Cl1-Cl10) were all 0.1-10 mg·L-1,with the same lower limits of determination (10S/N) of 0.1 mg·kg-1. Recovery rates obtained by standard addition method were in the range of 86.0%-109%,and RSDs (n=7) were within 10%.
中图分类号 O657.63 DOI 10.11973/lhjy-hx201511013
所属栏目 工作简报
基金项目 国家质检总局科技项目基金(2013zjjg050);广东省 质量技术监督局科技项目基金资助项目(2013PZ09)
收稿日期 2014/11/23
修改稿日期
网络出版日期
作者单位点击查看
备注幸苑娜(1983-),女,广东梅州人,主要从事消费品 中有害物质检测分析研究。
引用该论文: XING Yuan-na,FENG An-hong,LIN Zhi-hui,WANG Xin,GONG Ye-meng,CHEN Ze-yong. GC-MS Determination of Polychlorinated Biphenyls in Polymer Materials Used in Electrical and Electronic Products[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2015, 51(11): 1547~1551
幸苑娜,冯岸红,林志惠,王 欣,龚叶萌,陈泽勇. 气相色谱-质谱法测定电子电气产品聚合物材料中的多氯联苯含量[J]. 理化检验-化学分册, 2015, 51(11): 1547~1551
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】HUTZINGER O,SAFE S,ZITKO V. The chemistry of PCB′s[M]. Cleveland,Ohio: CRC Press,1974.
【2】高丹,刘劲松,朱国华,等.同位素稀释/高分辨气相色谱-质谱联用同时测定空气中二噁英、多氯联苯、多溴联苯醚和溴代二噁英[J].分析化学,2013,41(12):1862-1868.
【3】施跃锦,蔡美强,金米聪.超声波辅助离子液体顶空液相微萃取-气相色谱-质谱法测定水中多氯联苯[J].理化检验-化学分册,2011,47(6):629-632.
【4】佟玲,吴淑琪,杨佳佳.土壤与沉积物样品中多氯联苯总量的气相色谱-质谱法快速分析[J].分析测试学报,2010,29(4):398-402.
【5】王道玮,赵世民,金伟,等.加速溶剂萃取-固相萃取净化-气相色谱/质谱法测定沉积物中多氯联苯和多环芳烃[J].分析化学,2013,41(6):861-868.
【6】王玉飞,陈晓红,傅小红.气相色谱-串联质谱法测定生物样品中的多氯联苯和滴滴涕[J].色谱,2007,25(1):112-112.
【7】张光明.超声波处理多氯联苯微污染技术研究[J].给水排水,2003,29(3):30-33.
【8】邓敏军,罗艳,邓超冰.固相萃取-气相色谱-质谱法测定水中的19种多氯联苯[J].光谱实验室,2012,29(2):947-950.
【9】刘祥,崔进,佟丽丽,等.食品印刷包装材料中多氯联苯的气相色谱-串联质谱法测定及其基质效应探讨[J].分析试验室,2014,33(1):30-34.
【2】高丹,刘劲松,朱国华,等.同位素稀释/高分辨气相色谱-质谱联用同时测定空气中二噁英、多氯联苯、多溴联苯醚和溴代二噁英[J].分析化学,2013,41(12):1862-1868.
【3】施跃锦,蔡美强,金米聪.超声波辅助离子液体顶空液相微萃取-气相色谱-质谱法测定水中多氯联苯[J].理化检验-化学分册,2011,47(6):629-632.
【4】佟玲,吴淑琪,杨佳佳.土壤与沉积物样品中多氯联苯总量的气相色谱-质谱法快速分析[J].分析测试学报,2010,29(4):398-402.
【5】王道玮,赵世民,金伟,等.加速溶剂萃取-固相萃取净化-气相色谱/质谱法测定沉积物中多氯联苯和多环芳烃[J].分析化学,2013,41(6):861-868.
【6】王玉飞,陈晓红,傅小红.气相色谱-串联质谱法测定生物样品中的多氯联苯和滴滴涕[J].色谱,2007,25(1):112-112.
【7】张光明.超声波处理多氯联苯微污染技术研究[J].给水排水,2003,29(3):30-33.
【8】邓敏军,罗艳,邓超冰.固相萃取-气相色谱-质谱法测定水中的19种多氯联苯[J].光谱实验室,2012,29(2):947-950.
【9】刘祥,崔进,佟丽丽,等.食品印刷包装材料中多氯联苯的气相色谱-串联质谱法测定及其基质效应探讨[J].分析试验室,2014,33(1):30-34.
相关信息