Assessment of AC-corrosion Possibility of Buried Pipelines with Adjacent Strong Electric Lines
摘 要
强电线路与埋地管道共用一个走廊时管道上不可避免地产生次生交流干扰。当这一交流干扰电流密度达到一定极限后便会造成管道的交流腐蚀,危及管道设备乃至人身的安全。提出了管道上交流腐蚀的条件及控制指标的新观点,并对管道交流腐蚀的可能性进行评估。
Abstract
The induced alternative interference current generated on buried pipelines is inevitable when the buried pipelines are paralleled with strong electric lines in a relative short distance. AC-corrosion will occur on the buried pipelines when the density of the induced alternative interference current reaches a specific limit value. This phenomenon will jeopardize the buried pipelines and even threaten the personal safety. A new standpoint about the AC-corrosion conditions and its control index are proposed. More importantly, the AC-corrosion possibility of buried pipelines is properly assessed.
中图分类号 TG174.4 DOI 10.11973/fsyfh-201601011
所属栏目 专论
基金项目
收稿日期 2014/11/20
修改稿日期
网络出版日期
作者单位点击查看
备注王双平(1958-),高级工程师,本科,从事电气化铁路牵引供变电和交流干扰与防护研究和设计,
引用该论文: WANG Shuang-ping,SUN Zhen-yang,HU Shi-xin,LU Jia-yu. Assessment of AC-corrosion Possibility of Buried Pipelines with Adjacent Strong Electric Lines[J]. Corrosion & Protection, 2016, 37(1): 47
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】尹可华. 工频电场作用下的金属腐蚀[Z]. [出版地不详]:成都科技大学管道干扰科研组,1979.
【2】ISO 15589-1-2003 Petroleum and natural gas industries-cathodic protection of pipeline transportation systems-on-land pipelines[S].
【3】CEN/TS 15280: 2006 Evaluation of a.c.corrosion likelihood of buried pipelines-application to cathodically protected pipelines[S].
【4】CEOCOR 2000 A.C.corrosion on cathodically protected pipelines guidelines for risk assessment and mitigation measures[S].
【5】GB/T 50698-2011 埋地钢质管道交流干扰防护技术标准[S].
【6】胡士信,路民旭,杜艳霞. 管道交流腐蚀的新观点[J]. 腐蚀与防护,2010(6):419-424.
【7】董亮,路民旭,杜艳霞. 埋地管道交流腐蚀的研究进展[J]. 中国腐蚀与防护学报,2011(6):173-177.
【8】郭剑,曹玉杰,胡士信. 交流输电线路对输油输气管道电磁影响限值研究[J]. 电网技术,2008(2):17-20.
【9】贝克曼,施文克,普林兹. 阴极保护手册——电化学保护的理论与实践[J]. 胡士信,王向农,译. 北京: 化学工业出版社,2005.
【10】中国科学院福建物质结构研究所二部金属腐蚀与防护组. 交流电对地下油气管道电化学腐蚀及其阴极保护的影响[J]. 金属腐蚀与防护,1977(1):20-29.
【2】ISO 15589-1-2003 Petroleum and natural gas industries-cathodic protection of pipeline transportation systems-on-land pipelines[S].
【3】CEN/TS 15280: 2006 Evaluation of a.c.corrosion likelihood of buried pipelines-application to cathodically protected pipelines[S].
【4】CEOCOR 2000 A.C.corrosion on cathodically protected pipelines guidelines for risk assessment and mitigation measures[S].
【5】GB/T 50698-2011 埋地钢质管道交流干扰防护技术标准[S].
【6】胡士信,路民旭,杜艳霞. 管道交流腐蚀的新观点[J]. 腐蚀与防护,2010(6):419-424.
【7】董亮,路民旭,杜艳霞. 埋地管道交流腐蚀的研究进展[J]. 中国腐蚀与防护学报,2011(6):173-177.
【8】郭剑,曹玉杰,胡士信. 交流输电线路对输油输气管道电磁影响限值研究[J]. 电网技术,2008(2):17-20.
【9】贝克曼,施文克,普林兹. 阴极保护手册——电化学保护的理论与实践[J]. 胡士信,王向农,译. 北京: 化学工业出版社,2005.
【10】中国科学院福建物质结构研究所二部金属腐蚀与防护组. 交流电对地下油气管道电化学腐蚀及其阴极保护的影响[J]. 金属腐蚀与防护,1977(1):20-29.
相关信息