Design and Application of Special Gamma Ray Testing Tool for Butt Joint of Small Diameter Tube
摘 要
常用小径管焊接接头伽玛射线检测过程中, 射线源存在着固定不方便、不牢靠, 安装后稳定性不好等问题, 设计出小径管焊接接头伽玛射线检测专用工装并应用于工程实践。结果表明, 该工装可快捷、准确、稳固地固定射线源并能保持合适焦距, 提高了工作效率及工作安全性。
Abstract
The fix of gamma ray source in the process of radiographic testing of commonly used small butt joint has disadvantages. Through analysis and research, a specialized tool set was designed for the gamma radiation detection of small tube butt joint, which solved the problem of how to fix the ray source in a fast, accurate, stable manner and to maintain appropriate focus, thus improving the work efficiency and work safety.
中图分类号 TG115.28 DOI 10.11973/wsjc201605016
所属栏目 仪器研制
基金项目
收稿日期 2015/7/30
修改稿日期
网络出版日期
作者单位点击查看
备注徐承尧(1964-), 男, 高级技师, 主要从事炼油、化工装置无损检测施工及管理工作。
引用该论文: XU Cheng-yao,LI Peng,CHEN Yan-zai,YU Cheng-ke,YANG Ya-xing. Design and Application of Special Gamma Ray Testing Tool for Butt Joint of Small Diameter Tube[J]. Nondestructive Testing, 2016, 38(5): 66~68
徐承尧1,李鹏,陈厌灾,于成科,杨亚星. 小径管焊接接头伽玛射线检测专用工装设计与应用[J]. 无损检测, 2016, 38(5): 66~68