搜索热:失效分析 陶瓷
扫一扫 加微信
首页 > 期刊论文 > 论文摘要
埋地管道地铁杂散电流干扰的测试技术
          
A Detecting Technique of Metro Stray Current Interference on Buried Pipelines

摘    要
深圳地铁发展迅猛,泄漏到大地中的杂散电流可导致埋地管道腐蚀加速。对深圳地铁杂散电流干扰下的输水管道进行检测,确定管道的自腐蚀电位,探讨试片材质和表面状态对检测结果的影响,同时研究了管道受杂散电流干扰的规律。结果表明: 杂散电流干扰程度与地铁和管道的相对位置有一定的关系,随着管道与地铁间距离减小,管道受到杂散电流干扰越来越严重;并且在相同距离下,交叉段受到干扰程度要大于平行段。同时不同材质的管道抗干扰能力也不相同。
标    签 地铁杂散电流   输水管道   自腐蚀电位   干扰规律   metro stray current   water pipeline   corrosion protential   interference rule  
 
Abstract
With the rapid development of Shenzhen metro, the leaked stray current into ground leads to corrosion of buried pipelines accelerated. A comprehensive inspection of water pipelines in different areas of Shenzhen under the interference of stray current was conducted, and the corrosion potential was determimed. The effects of materials and surface conditions of samples on the detection results were discussed. And a certain of stray current interference rules on pipelines were obtained. The results show that there is some relationship between the relative position and the degree of metro stray current interference on pipelines. With the decrease of the distance between pipelines and metro, the stray current interference becomes more serious; and in the same distance, the interference degree of the pipelines crossed with metro is higher than that of parallel with metro. At the same time, the ability of anti-interference of different materials is in difference.

中图分类号 TG172.84   DOI 10.11973/fsyfh-201605001

 
  中国光学期刊网论文下载说明


所属栏目 腐蚀监检测技术

基金项目 国家自然科学基金(51401017); 中央高校基本科研业务费专项资金(FRF-TP-14-096A2); 深圳水务集团输水管道杂散电流干扰测试及评估项目资助

收稿日期 2015/3/18

修改稿日期

网络出版日期

作者单位点击查看


备注杜艳霞(1980-),副教授,博士,从事阴极保护的工作,

引用该论文: MENG Qing-si,DU Yan-xia,DONG Liang,DAI Shu,XU Hong-fu. A Detecting Technique of Metro Stray Current Interference on Buried Pipelines[J]. Corrosion & Protection, 2016, 37(5): 355


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】吴祥祖,张庆贺,高卫平. 地铁杂散电流产生机理及其防护措施[J]. 建筑安全,2003(5): 28-30.
 
【2】LINDEMUTH D,CRABTREE D. AC and DC stray current mitigation and corrosion control for a new urban pipeline[C]//Corrosion 2012. Atlanta,TX: NACE,2012.
 
【3】张丰,齐晓忠,金宏,等. 试片断电法在管道阴极保护中的应用[J]. 油气储运,2013,32(7): 760-763.
 
【4】杨敬杰. 地铁直流干扰影响下管道阴保电位的测试和评价[J]. 腐蚀与防护,2014,35(3): 288-291.
 
【5】CHEN Z G,QIN C K,TANG J X,et al. Experiment research of dynamic stray current interference on buried gas pipeline from urban rail transit[J]. Journal of Natural Gas Science and Engineering,2013(15): 76-81.
 
【6】CASAS R D R,TURNER R,ROE K. Dynamic stray current interference testing and mitigation design for a 90-inch water main[C]//Corrosion 2009. Atlanta,TX: NACE,2009.
 
【7】NACE TM 0497-2002 Measurement techniques related to criteriafor cathodic protection on undergroundor submerged metallic piping systems[S].
 
【8】SY/T 0017-2006 埋地钢质管道直流排流保护技术标准规定[S].
 
【9】SY/T 0029-2012 埋地钢质检查片应用技术规范[S].
 
相关信息
   标题 相关频次
 导管架牺牲阳极阴极保护数值模拟评价与优化改造
 4
 地铁杂散电流对埋地管道的干扰规律
 4
 3PE防腐蚀层失效分析与寿命预测
 2
 北京燃气管道牺牲阳极服役参数测试及变化规律
 2
 北京受地铁杂散电流干扰埋地燃气管道的现场检测与防护方案
 2
 长效铜/饱和硫酸铜参比电极的研究进展
 2
 沉积砂对X60钢在饱和CO2油田水中腐蚀行为的影响
 2
 地铁杂散电流干扰下埋地管道管地电位动态波动规律
 2
 动态直流杂散电流干扰下埋地管道的腐蚀行为
 2
 环境介质对动态直流干扰下X80钢腐蚀行为的影响
 2
 交流干扰对埋地管线阴极保护的影响
 2
 胶日线天然气管道交流干扰评估与缓解
 2
 接地材料对埋地金属管道阴极保护效果及电流需求量的影响
 2
 接地系统对区域阴极保护影响规律及解决措施研究现状
 2
 廉溪大道并行天然气管道腐蚀风险检测与分析
 2
 埋地管道交流干扰缓解效果影响因素
 2
 某海管阴极保护状况评估及牺牲阳极更换的优化
 2
 输油泵站区域性阴极保护实施中的问题
 2
 四种交流排流器服役性能对比
 2
 苏州地区管道受地铁杂散电流干扰的规律
 2
 条形电阻探针电阻变化与腐蚀程度相关性的数值模拟
 2
 牺牲阳极截面形状对其服役性能的影响
 2
 X70管线钢交流腐蚀的影响因素
 1
 饱和CO2盐溶液中镍基合金和碳钢的电偶腐蚀行为
 1
 北京燃气管网外腐蚀泄漏的关键影响因素
 1
 超级电容储能供电型有轨电车对埋地钢质管道杂散电流干扰的影响
 1
 城市小区低压燃气管网开放式阴极保护方式及地床形式优化
 1
 城镇基础设施对油气管道的干扰规律及其识别方法
 1
 地铁轨电位限制装置对埋地管道杂散电流干扰的影响
 1
 地铁检修基地杂散电流对高压天然气管道的干扰及治理措施
 1