搜索热:失效分析 陶瓷
扫一扫 加微信
首页 > 期刊论文 > 论文摘要
上海虹桥机场航油输送管道受地铁杂散电流干扰的检测与防护
          
Interference Detection and Protection of Subway Stray Current Interference on Shanghai HongQiao Aeri-oil Pipeline

摘    要
虹桥机场航油管道受地铁直流杂散电流影响,部分管道阴极保护电位无法达到保护要求,管道存在极高的电化学腐蚀风险。对航油管道的干扰情况进行检测,采取以排流保护和阴极保护相结合的综合防护措施。结果表明: 管道保护电位达到保护要求,地铁对管道造成的杂散电流干扰危害得到有效消除。
标    签 地铁杂散电流   航油管道   干扰检测   干扰防护   subway stray current   aerioil pipeline   interference detection   interference protection  
 
Abstract
Due to the serious DC stray current interference caused by subway, part of pipeline in HongQiao airport aeri-oil pipeline couldn′t meet the protection requirements, high risk of electrochemical corrosion existed. The interference on the pipeline was tested, and the combination of discharge protection and cathodic protection was taken. The results showed that the cathodic protection potential of the pipeline could meet the protection requirement, and the hazard of subway stray current interference on pipeline was effectively eliminated.

中图分类号 TG174.41   DOI 10.11973/fsyfh-201605003

 
  中国光学期刊网论文下载说明


所属栏目 腐蚀监检测技术

基金项目

收稿日期 2015/6/16

修改稿日期

网络出版日期

作者单位点击查看


备注马晓华(1968-),工程师,硕士,从事民用航空燃料设施的建设、运营及安全管理工作,

引用该论文: MA Xiao-hua. Interference Detection and Protection of Subway Stray Current Interference on Shanghai HongQiao Aeri-oil Pipeline[J]. Corrosion & Protection, 2016, 37(5): 364


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】杨义军,李文玉,王芷芳,等. 极化探头在埋地钢质管道阴极保护的应用[J]. 煤气与热力,2010,30(4): 24-27.
 
【2】林江,唐华,于海学,等. 地铁迷流腐蚀及其防护技术[J]. 建筑材料学报,2002,5(1): 72-76.
 
【3】颜达峰,刘乃勇,袁鹏斌,等. 地铁维修基地杂散电流对埋地钢质制管道的腐蚀及防护措施[J]. 腐蚀与防护,2013,34(8): 739-742.
 
相关信息
   标题 相关频次
 北京受地铁杂散电流干扰埋地燃气管道的现场检测与防护方案
 2
 地铁检修基地杂散电流对高压天然气管道的干扰及治理措施
 2
 地铁杂散电流干扰下埋地管道管地电位动态波动规律
 2
 地铁杂散电流干扰下试片法测试埋地钢质管道断电电位
 2
 管道地铁杂散电流干扰腐蚀风险评估与防护措施
 2
 埋地管道地铁杂散电流干扰源头控制法
 2
 地铁杂散电流对埋地管道的干扰规律
 1
 埋地管道地铁杂散电流干扰的测试技术
 1
 苏州地区管道受地铁杂散电流干扰的规律
 1
 直流杂散电流对天然气管道干扰影响案例分析
 1