Analysis of the Abnormality during Ultrasonic Thickness Gauging for a Steel Plate
摘 要
某压力容器用钢板测厚时出现了厚度显示异常现象,钢板中部厚度均为实际厚度的一半左右。通过采用超声波检测、表面检测、力学性能测试、酸蚀检验和射线检测等方法进行试验,分析了导致钢板厚度显示异常的原因。分析表明,超声波测厚和检测中发现的异常现象是由钢板中低倍组织造成的,是组织反射的结果,而侧弯不合格是由于钢板中心偏析所致。结果可为钢厂加强冶炼工艺、冶炼技术的改进和控制提供借鉴。
Abstract
While measuring the thickness for a pressure vessel steel plate abnormal display often occurred with the thickness at the plate central being about half of the actual value. A series of tests, including ultrasonic testing, surface inspection, mechanical properties test, acid etch test and radiographic detection method tests, were conducted to analyze the cause of the abnormal display. Results show that, the abnormal phenomenon appearing in ultrasonic thickness test is caused by the plate low times microstructure and is the result of reflecting tissue. And the unqualified lateral bending is due to the segregation of steel plate center. The above-mentioned results may provide reference for the steel mills to strengthen smelting process and smelting technology to improve and control the steel quality.
中图分类号 TG115.28 DOI 10.11973/wsjc201606011
所属栏目 试验研究
基金项目
收稿日期 2015/12/7
修改稿日期
网络出版日期
作者单位点击查看
备注侯耀民(1971-),男,工程师,学士,主要从事无损检测工作。
引用该论文: HOU Yao-min,HOU Jia-yong. Analysis of the Abnormality during Ultrasonic Thickness Gauging for a Steel Plate[J]. Nondestructive Testing, 2016, 38(6): 45~47
侯耀民,侯家永. 钢板超声测厚检测异常显示的分析[J]. 无损检测, 2016, 38(6): 45~47
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GB 6654-1996 压力容器用钢板[S].
【2】JB 4744-2002 钢制压力容器产品焊接试板的力学性能检验[S].
【3】GB/T 226-1991 钢的低倍组织及缺陷酸蚀检验法[S].
【4】强天鹏. 射线检测[M]. 北京: 中国劳动社会保障出版社, 2007.
【5】GB/T 1979-2001 结构钢低倍组织缺陷评级图[S].
【2】JB 4744-2002 钢制压力容器产品焊接试板的力学性能检验[S].
【3】GB/T 226-1991 钢的低倍组织及缺陷酸蚀检验法[S].
【4】强天鹏. 射线检测[M]. 北京: 中国劳动社会保障出版社, 2007.
【5】GB/T 1979-2001 结构钢低倍组织缺陷评级图[S].
相关信息