摘    要
某430铁素体不锈钢餐具在进行重金属迁移量检验时,发现铬离子析出量严重超标。通过电化学动电位再活化法测试该430铁素体不锈钢试样的腐蚀敏感性,利用光学显微镜、扫描电镜、能谱仪对试样的腐蚀形貌、显微组织和表面碳、铬元素分布情况进行分析。结果表明:在430铁素体不锈钢餐具的生产过程中,由于热处理工艺不当导致杂质碳化物的偏析以及马氏体残余,进而在腐蚀介质中发生原电池腐蚀反应,最终导致铬离子析出量超标。
标    签 铁素体不锈钢   餐具   铬离子析出量   超标   碳化物   原电池腐蚀   ferritic stainless steel   utensil   emanation quantity of chromium ion   over-proof   carbide   galvanic corrosion  
 
Abstract
The over-proof of chromium ions released from 430 ferritic stainless steel utensils was found during heavy metal migration test. The corrosion susceptibility of the 430 ferritic stainless steel samples was evaluated by electrochemical potentiodynamic reactivation method. And the corrosion morphology, microstructure, distribution of carbon and chromium elements of the samples were analyzed by optical microscopy, scanning electron microscopy and energy dispersive spectroscopy. The results show that the improper heat-treatment of the 430 ferritic stainless steel utensils during the production process led to the generation of impurity carbide segregation and residual martensite. Then the galvanic corrosion happened in the corrosive medium, and eventually resulted in the emanation quantity over-proof of chromium ions.

中图分类号 TG172.9   DOI 10.11973/lhjy-wl201607012

 
  中国光学期刊网论文下载说明


所属栏目 质量控制与失效分析

基金项目

收稿日期 2015/10/26

修改稿日期

网络出版日期

作者单位点击查看


备注黄子东(1987-),男,硕士,主要从事金属材料电化学腐蚀方面的工作

引用该论文: HUANG Zi-dong,JIANG Yi-kui,CHEN Hui-bo,CHEN Li-ling,LIN Jun-ming,HONG Ze-hao,WEI Liang-xin. Reasons Analysis on Emanation Quantity Over-proof of Chromium Ions in Ferritic Stainless Steel Utensils[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2016, 52(7): 489~493
黄子东,江乙逵,陈惠波,陈丽玲,林俊铭,洪泽浩,魏亮新. 铁素体不锈钢餐具铬离子析出量超标的原因分析[J]. 理化检验-物理分册, 2016, 52(7): 489~493


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】陆世英, 张廷凯,杨长强,等.不锈钢[M].北京:原子能出版社,1995:102.
 
【2】李晓波.国内铁素体不锈钢的最新发展[J].铸造设备研究,2006,4(4):52-54.
 
【3】GB/T 9684-2011 食品安全国家标准 不锈钢制品[S].
 
【4】赵敏,寇海娟.国内外食品接触用不锈钢制品法规的分析比较[J].科技致富向导,2014(24):187-188.
 
【5】金维松,朗宇平,荣凡.EPR法评价奥氏体不锈钢晶间腐蚀敏感性的研究[J].中国腐蚀与防护学报,2007,27(1):54-59.
 
【6】邵泽斌,陈海涛,朗宇平,等.430铁素体不锈钢晶间腐蚀敏感性评测方法及影响因素[J].特殊钢,2012,33(5):57-60.
 
【7】LOPEZ N,CID M,PUIGGALI M,et al.Application of double loop electrochemical potentiodynamic reactivation test to austenitic and duplex stainless steels[J].Materials Science & Engineering A,1997,229:123-128.
 
【8】AMADOU T,BRAHAM C,SIDHOM H.Double loop electrochemical potentiokinetic reactivation test optimization in checking of duplex stainless steel intergranular corrosion susceptibility[J]. Metallurgical & Materials Transaction A,2004,35(11):3499-3513.
 
【9】SINYAVSKII V S,LANOVA V V,KALININ V D.On the mechanism of intergranular corrosion of aluminum[J].Protection of Metals,2004,40(5):537-539.
 
【10】印有胜.关于铁素体不锈钢焊接晶间腐蚀的若干问题[J].焊接学报,1996,17(1):39-47.
 
【11】肖纪美.不锈钢的金属学问题[M].北京:冶金工业出版社,2006:172.
 
【12】吴剑.不锈钢的腐蚀破坏与防蚀技术:(三)晶间腐蚀[J].腐蚀与防护,1997,18(3):137-140.
 
【13】邵泽斌.铁素体不锈钢晶间腐蚀检测控制及其对表面质量的影响[D].昆明:昆明理工大学,2012.
 
相关信息
   标题 相关频次
 敏化对430铁素体不锈钢铬离子析出量的影响
 7
 Cr12钢水胀模具底座断裂原因分析
 6
 304不锈钢防盗罩锈蚀原因分析
 4
 电化学动电位再活化法评价热处理对430不锈钢晶间腐蚀敏感性的影响
 4
 使用电化学动电位再活化法研究热处理工艺对304不锈钢晶间腐蚀敏感性的影响
 4
 430不锈钢锅干烧后铬离子析出量超标的原因
 3
 敏化处理后304不锈钢的电化学腐蚀性能
 3
 1.4003铁素体不锈钢与Q235-C钢焊接接头的组织和力学性能
 2
 12Cr1MoV珠光体耐热钢长期服役中碳化物的变化及对性能的影响
 2
 13MnNiMoR钢热冲压封头冲击韧度显著降低原因分析
 2
 1Cr17不锈钢表面TIG冷焊重熔和丝材熔敷工艺及改性层的组织和性能
 2
 20CrNiMo钢零件渗碳表层淬火开裂原因分析
 2
 40Cr钢等温淬火形成的下贝氏体组织形貌特征
 2
 443铁素体不锈钢电阻缝焊接头的组织与性能
 2
 4Cr2Mo2W2V热作模具钢的高温抗压性能
 2
 690合金锻造棒材中的细晶带对成品管组织的影响
 2
 690耐蚀合金管材晶粒度和碳化物形貌分析用金相侵蚀剂的选择
 2
 C22哈氏合金换热器腐蚀原因及其防护措施
 2
 Cr12钢冷冲模具加工过程中开裂原因分析
 2
 GCr15轧辊热处理爆裂失效分析
 2
 GCr15轴承钢球化退火碳化物的定量分析
 2
 GCr15轴承钢中碳化物的定量分析
 2
 GH864合金在超温条件下的组织性能变化
 2
 HP-Nb合金转化炉管服役过程中的损伤规律
 2
 K360耐磨钢堆焊合金层的组织与性能
 2
 M2高速钢盘条退火工艺的优化
 2
 S136钢模具断裂的原因
 2
 Si在半高速钢HYRH12中的作用
 2
 TP439不锈钢在高温高压水中的应力腐蚀开裂行为
 2
 X光管用联轴轴承滚道处麻点成因分析
 2