Detection of Broken and Weak Points of Detonating Cord Based on Non-contact Air Coupled Ultrasonic
摘 要
导爆索断细药的检测方法多为接触式,存在有安全隐患、检测效率较低的问题,提出了一种基于空气耦合超声的导爆索断细药检测方法。通过对药芯的非接触检测实现对断细药情况的快速测量。使用空气耦合超声检测法可有效提高导爆索断细药的检测效率和检测精度。
Abstract
The detonating cable fault detection methods are mostly of contact type and these methods have hidden danger and the detection efficiency is low. In order to solve the above problems, this paper presents a new method based on air coupled ultrasound for the detection of the broken and weak points,through the non-contact detection of the drug core of the detonating cable the broken and weak points could be quickly found. Experimental results show that the method can effectively improve the detection efficiency and precision of the real-time detection of the broken and weak Points.
中图分类号 TQ565 TG115.28 DOI 10.11973/wsjc201607011
所属栏目 试验研究
基金项目 国家自然科学基金资助项目(6171177);山西省青年科技研究基金资助项目(2015021086)
收稿日期 2016/2/2
修改稿日期
网络出版日期
作者单位点击查看
联系人作者李光亚(40827562@qq.com)
备注李光亚(1980-),男,讲师,博士,主要研究方向为测试计量技术与仪器。
引用该论文: LI Guang-ya,WANG Ming-quan,ZHENG Jing-yi. Detection of Broken and Weak Points of Detonating Cord Based on Non-contact Air Coupled Ultrasonic[J]. Nondestructive Testing, 2016, 38(7): 44~45
李光亚,王明泉,郑景义. 基于空气耦合超声的导爆索断细药检测[J]. 无损检测, 2016, 38(7): 44~45
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】雷丽文,缪均达.工业导火索断细药疵病的在线检测[J].爆破器材,1996(2):1-4.
【2】黄寅生,杨贵华,臧小为.铝壳金属导爆索性能研究[J].爆破器材,2008,37(3):22-24.
【3】刘钧,李俊杰,孙安昌,等.火工品管壳内径尺寸检测方法研究[J].火工品,2006(4):37-41.
【4】陈浩,邾继贵,杨学友,等.新型多方向内径尺寸测量方法[J].仪表技术与传感器,2011(1):95-97.
【5】GB 9786-1999普通导爆索[S].
【6】李光亚,王明泉,郑景义.基于超声的铅皮导爆索断细药检测方法研究[J].兵工学报,2013,34(8):1037-1040.
【2】黄寅生,杨贵华,臧小为.铝壳金属导爆索性能研究[J].爆破器材,2008,37(3):22-24.
【3】刘钧,李俊杰,孙安昌,等.火工品管壳内径尺寸检测方法研究[J].火工品,2006(4):37-41.
【4】陈浩,邾继贵,杨学友,等.新型多方向内径尺寸测量方法[J].仪表技术与传感器,2011(1):95-97.
【5】GB 9786-1999普通导爆索[S].
【6】李光亚,王明泉,郑景义.基于超声的铅皮导爆索断细药检测方法研究[J].兵工学报,2013,34(8):1037-1040.
相关信息