The Recovery Method of Altered VIN
摘 要
目前,国内对磨损后机动车车架号码的复现有两种方法: 一种是通过化学试剂(酸与金属化学反应)的擦洗进行复现, 另一种是应用车架号磁性显现仪器进行复现。通过试验对两种方法的复现效果进行比较, 结果显示, 磁性复现方法的优点在于简便, 但其复现效果与化学试剂擦洗方法比较并没有优势, 且仪器价格较贵, 在检验鉴定实践中的应用存在一定的局限性。
Abstract
Nowadays there are two main methods used for the recovery of altered VIN in China. One is scrubbing with chemicals (chemical reaction between metal and acid), the other is magnetic recover by the related instrument. In this paper, the results of these two methods are compared to show that the advantage of the latter one is simple and convenient, but the effect of its appearance is not superior to the chemical reagent cleaning method. In addition, the price of the instrument is more expensive and its application in the inspection and appraisal practice has certain limitations.
中图分类号 TG115.28 DOI 10.11973/wsjc201610017
所属栏目 试验研究
基金项目
收稿日期 2016/4/15
修改稿日期
网络出版日期
作者单位点击查看
备注贾常明(1967-), 男, 副教授, 主要从事交通事故鉴定研究。
引用该论文: JIA Chang-ming. The Recovery Method of Altered VIN[J]. Nondestructive Testing, 2016, 38(10): 72~74
贾常明. 磨损后的机动车车架号的复现方法[J]. 无损检测, 2016, 38(10): 72~74
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差