Correction of Defect Indication Length in Ultrasonic Testing
摘 要
NB/T 47013.3-2015超声检测标准中, 对Ⅱ型焊接接头给出了缺陷实际指示长度的修正公式, 但在实际超声检测中, 由于声场、工件几何形状的影响, 缺陷的实际指示长度与测量值之间存在偏差, 精确评定时需要修正。针对超声检测中曲率表面工件的外圆柱面、内圆柱面沿周向测出的缺陷指示长度的修正问题, 进行了讨论。得出结论: 如本着从严的原则, 对外圆柱面检测可以不进行修正的话, 那么对内圆柱面检测结果则应进行修正, 才能使产品符合标准的要求。
Abstract
The formula indicating the actual length of the defect in the ultrasonic detection of welded joint is given in NB/T 47013.3-2015 ultrasonic testing standards, but in fact, because the sound effect of the workpieces, the deviation between the actual length and value measurement of defect indication exists, and therefore precise timing evaluation needs to be revised. Ultrasonic testing for the workpiece surface curvature in the outer cylindrical correction within the cylindrical surface along the circumferential direction of the measured length of flaw indication was discussed. Conclusions might be drawn that in the strict term in order to make the products meet the requirements of the standard, if the external cylindrical surface detection can not be modified, then the inner cylindrical surface detection should be modified.
中图分类号 TG115.28 DOI 10.11973/wsjc201612006
所属栏目 2016远东无损检测新技术论坛论文精选
基金项目
收稿日期 2016/6/22
修改稿日期
网络出版日期
作者单位点击查看
备注许遵言(1956-), 男, 教授级高级工程师, 主要从事特种设备和民用核设备的无损检测。
引用该论文: XU Zun-yan,HUANG Qing-jun,WU Zheng-biao. Correction of Defect Indication Length in Ultrasonic Testing[J]. Nondestructive Testing, 2016, 38(12): 25~27
许遵言,黄庆军,吴正彪. 超声检测中缺陷显示长度的修正[J]. 无损检测, 2016, 38(12): 25~27
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】郑晖,林树青.超声检测[M].北京:中国劳动社会保障出版社, 2007.
【2】克劳特克洛默 J,克劳特克洛墨 H.超声检测技术[M].李靖, 马羽宽, 蔡清福, 等, 译.广州: 广东科技出版社, 1984.
【2】克劳特克洛默 J,克劳特克洛墨 H.超声检测技术[M].李靖, 马羽宽, 蔡清福, 等, 译.广州: 广东科技出版社, 1984.
相关信息