Mutual Influence between Cathodic Protection Systems of Pipelines at Linyi Station
摘 要
临邑站存在多条管线,不同管线采用相互独立的阴极保护系统,通过现场试验,考察了不同阴极保护系统的相互影响情况。结果表明:鲁宁线阴极保护系统对临濮线阴极保护系统存在影响,历史资料调研表明这两条管线间存在相互跨接,但跨接位置不明;综合利用现场跨接试验、多频管中电流法(PCM)测试以及阴极保护电位测试等方法确定了跨接线的位置。
Abstract
There are some pipelines at Linyi oil/gas station, and each of pipelines has own cathodic protection system respectively. The case of mutual influence between cathodic protection systems was investigated through field test. The results indicate that the cathodic protection system of Luning line had some influence on the cathodic protection system of Linpu line. The historical data research shows that these two pipelines were connected by a jumper wire, but the connected location was uncertain. The location of jumper wire was found by means of field bonding test, pipeline current mapper (PCM) test and cathodic protection potential test.
中图分类号 TG174.41 DOI 10.11973/fsyfh-201704016
所属栏目 应用技术
基金项目
收稿日期 2015/6/18
修改稿日期
网络出版日期
作者单位点击查看
联系人作者曹国民(freecgm@163.com)
引用该论文: CAO Guo-min. Mutual Influence between Cathodic Protection Systems of Pipelines at Linyi Station[J]. Corrosion & Protection, 2017, 38(4): 322
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】方卫林,李振军,洪娜,等. 典型站场区域阴极保护系统对线路阴极保护系统干扰的检测及处理[J]. 腐蚀与防护,2015,36(3):272-275.
【2】刘玲莉,陈洪源,刘明辉,等. 输油气站区阴极保护中的干扰与屏蔽[J]. 管道技术与设备,2005(2):31-33.
【3】毕武喜,刘月发,赵君,等. 油气管道阴极保护阳极干扰检测与分析[J]. 腐蚀与防护,2013(12):1111-1113.
【4】代以斌,孙春良,单蕾,等. 长输油气管道并行敷设阴极保护防干扰分析[J]. 石油与天然气化工,2010,39(6):557-560.
【5】刘志远. 地下管线阴极保护系统的干扰腐蚀问题[J]. 煤气与热力,1996(4):7-8.
【6】耿铂,余越泉. PCM管道电流检测系统介绍及应用[J]. 腐蚀与防护,2002,23(1):21-23.
【2】刘玲莉,陈洪源,刘明辉,等. 输油气站区阴极保护中的干扰与屏蔽[J]. 管道技术与设备,2005(2):31-33.
【3】毕武喜,刘月发,赵君,等. 油气管道阴极保护阳极干扰检测与分析[J]. 腐蚀与防护,2013(12):1111-1113.
【4】代以斌,孙春良,单蕾,等. 长输油气管道并行敷设阴极保护防干扰分析[J]. 石油与天然气化工,2010,39(6):557-560.
【5】刘志远. 地下管线阴极保护系统的干扰腐蚀问题[J]. 煤气与热力,1996(4):7-8.
【6】耿铂,余越泉. PCM管道电流检测系统介绍及应用[J]. 腐蚀与防护,2002,23(1):21-23.