Effect of Mg on Microstructure of Hot-dip Galvanized Zinc-based Alloy Coatings
摘 要
采用热浸镀方法在Q235钢板表面制备了Mg的质量分数分别为0.0%,0.1%,0.3%,0.5%的锌基合金镀层。利用扫描电子显微镜(SEM)、能谱仪(EDS)、辉光光谱仪(GDOES)等手段分析了Mg含量变化对镀层组织结构的影响。结果表明:随着镀层中Mg含量的增加,合金镀层的表面晶粒逐渐变小;Mg元素富集于晶界之中,起到细化晶粒的作用;Mg推迟了ζ相向δ相的转变,使镀层结构中的δ相层减薄。
Abstract
Hot-dip galvanizing was used to prepare zinc-based alloys on the surface of Q235 steel sheet. The alloys contains various Mg contents of 0wt%, 0.1wt%, 0.3wt%, 0.5wt%, respectively. SEM, EDS and GDOES were used to analyze the effect of Mg content on the microstructure of alloys. The results show that with the increase of the content of Mg in the coating, the grain size of coating decreased. Mg segregated in grain boundaries and played a role of fining the grain size. Mg is capable of hindering the transformation of ζ phase to δ phase, resulting in thin δ phase layer.
中图分类号 TG174 DOI 10.11973/fsyfh-201705015
所属栏目 试验研究
基金项目
收稿日期 2017/2/9
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: YU Wugang,LI Yuanpeng,LIU Canlou,JIANG Sheming,ZHANG Qifu. Effect of Mg on Microstructure of Hot-dip Galvanized Zinc-based Alloy Coatings[J]. Corrosion & Protection, 2017, 38(5): 387
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】樊志彬,李辛庚. 输电杆塔钢构件腐蚀防护技术现状和发展趋势[J]. 山东电力技术,2013,191(1):30-34.
【2】陈云,徐利民,药宁娜,等. 输变电钢构件的大气腐蚀与防护[J]. 华北电力技术,2014,12:10-14.
【3】陈军君,胡加瑞,谢亿,等. 典型工业区输变电线路金具腐蚀失效分析[J]. 腐蚀科学与防护技术,2013,25(6):508-513.
【4】陈彤,谈天,洪毅成,等. 输电网镀锌金属部件的腐蚀与防护[J]. 中国电力,2013,46(11):1-7.
【5】胡俊鹏,李辛庚,岳增武,等. 输变电钢构件热镀锌防腐效果调查分析[J]. 腐蚀科学与防护技术,2014,26(6):567-570.
【6】SHINDO H,NISHIMURA K. Developments and properties of Zn-Mg galvanized steel sheet "DYMAZINC" having excellent corrosion resistance[J]. Nippon Steel Technical Report,1999,79:63-67.
【7】DUTTA M,HALDER A K,SINGH S B. Morphology and properties of hot dip Zn-Mg and Zn-Al-Mg alloy coating on steel sheet[J]. Surface and Coating Technology,2010,25(10):2578-2584.
【8】吴长军,尹力,苏旭平,等. ZnFeMg三元系450℃等温截面实验测定[C]//第十六届全国相图学术会议暨相图与材料设计国际研讨会. 常州:[出版者不详],2012:350-351.
【9】曲家惠,金浩,王福,等. 镁对IF钢热镀锌镀层的组织和性能的影响[J]. 腐蚀科学与防护技术,2008,20(1):9-11.
【2】陈云,徐利民,药宁娜,等. 输变电钢构件的大气腐蚀与防护[J]. 华北电力技术,2014,12:10-14.
【3】陈军君,胡加瑞,谢亿,等. 典型工业区输变电线路金具腐蚀失效分析[J]. 腐蚀科学与防护技术,2013,25(6):508-513.
【4】陈彤,谈天,洪毅成,等. 输电网镀锌金属部件的腐蚀与防护[J]. 中国电力,2013,46(11):1-7.
【5】胡俊鹏,李辛庚,岳增武,等. 输变电钢构件热镀锌防腐效果调查分析[J]. 腐蚀科学与防护技术,2014,26(6):567-570.
【6】SHINDO H,NISHIMURA K. Developments and properties of Zn-Mg galvanized steel sheet "DYMAZINC" having excellent corrosion resistance[J]. Nippon Steel Technical Report,1999,79:63-67.
【7】DUTTA M,HALDER A K,SINGH S B. Morphology and properties of hot dip Zn-Mg and Zn-Al-Mg alloy coating on steel sheet[J]. Surface and Coating Technology,2010,25(10):2578-2584.
【8】吴长军,尹力,苏旭平,等. ZnFeMg三元系450℃等温截面实验测定[C]//第十六届全国相图学术会议暨相图与材料设计国际研讨会. 常州:[出版者不详],2012:350-351.
【9】曲家惠,金浩,王福,等. 镁对IF钢热镀锌镀层的组织和性能的影响[J]. 腐蚀科学与防护技术,2008,20(1):9-11.
相关信息