Effect of Inductance and pH Corrosion Measuring System on Circulating Water Treatment in Power Plant
摘 要
从电厂循环水系统腐蚀特点与机理的方面讨论了循环水系统的防腐蚀工作重点,有针对性地采用电感及pH腐蚀测量系统来指导循环水处理与设备防腐蚀。通过在天津大唐盘山发电有限责任公司(以下称大唐盘电)3号凝汽器上的应用,验证了其有效性。
Abstract
The key point of anticorrosion work for circulating water system was discussed in the aspects of corrosion characteristics and mechanism for circulating water in power plants. Inductance and pH corrosion measurement system was used to guide the circulating water treatment and equipment anticorrosion. Through the application to the 3# condenser of Tianjin Datang Panshan Power Limited Liability Company (hereinafter referred to as the Datang Panshan Power), the effect of the system was proved.
中图分类号 TG174 DOI 10.11973/fsyfh-201705018
所属栏目 应用技术
基金项目
收稿日期 2015/8/6
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: YANG Fulin,ZHANG Xiuli,ZHANG Hongjie,KANG Cunjun. Effect of Inductance and pH Corrosion Measuring System on Circulating Water Treatment in Power Plant[J]. Corrosion & Protection, 2017, 38(5): 398
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】周本省. 工业水处理技术[M]. 北京:化学工业出版社,1996:169.
【2】杨富淋. 腐蚀在线监测技术在电厂循环冷却水系统中的应用[J]. 华北电力技术,2012(4):14-17.
【3】房金祥. 酸洗/缓蚀阻垢/杀菌/旁虑法提高热电厂循环水浓缩倍率[J]. 腐蚀与防护,2006,27(9):472-477.
【4】葛红花,陈霞,张慧鑫,等. 不同水质稳定剂对凝汽器不锈钢管的缓蚀性能[J]. 中国电力,2007,35(4):17-19.
【5】许立国. 某火电厂凝汽器铜管初期腐蚀的原因[J]. 腐蚀与防护,2010,31(1):92-94.
【2】杨富淋. 腐蚀在线监测技术在电厂循环冷却水系统中的应用[J]. 华北电力技术,2012(4):14-17.
【3】房金祥. 酸洗/缓蚀阻垢/杀菌/旁虑法提高热电厂循环水浓缩倍率[J]. 腐蚀与防护,2006,27(9):472-477.
【4】葛红花,陈霞,张慧鑫,等. 不同水质稳定剂对凝汽器不锈钢管的缓蚀性能[J]. 中国电力,2007,35(4):17-19.
【5】许立国. 某火电厂凝汽器铜管初期腐蚀的原因[J]. 腐蚀与防护,2010,31(1):92-94.