The Magnification of Microfocus X-ray Digital Radiography System
摘 要
概述了微焦点X射线数字成像系统放大倍数的定义,分析了微焦点X射线数字成像系统几个关键部分的放大原理,分别提出了使用搭载图像增强器与CCD相机、平板探测器的参数来计算微焦点X射线成像装置的系统放大倍数的公式。结合试验数据,验证了公式的正确性,该公式可以用在成像方式相类似的,包括直接和间接的数字成像系统上。
Abstract
The article discussed various definitions about magnification of microfocus X-ray digital radiography system, explained the theory of the microfocus X-ray digital radiography system magnification in a digital radiography with image intensifier,CCD camera and flat panel detector. Combined with the experimental data, the correctness of the formula is verified, and the formula can be used in imaging methods similar to those including direct and indirect digital radiography systems.
中图分类号 TG115.28 DOI 10.11973/wsjc201707010
所属栏目 试验研究
基金项目
收稿日期 2016/12/1
修改稿日期
网络出版日期
作者单位点击查看
备注杨龙(1987-),男,本科,工程师,主要从事X射线数字成像检测系统性能研究和相关微焦点X射线数字成像领域标准的制定工作
引用该论文: YANG Long. The Magnification of Microfocus X-ray Digital Radiography System[J]. Nondestructive Testing, 2017, 39(7): 46~48
杨龙. 微焦点X射线数字成像系统中的放大倍数[J]. 无损检测, 2017, 39(7): 46~48