Discrimination of False Defects in Ultrasonic Testing of Small Diameter Pipes
摘 要
通过对小径管(外径为 32~89 mm,壁厚为4~8 mm)超声检测中疑似缺陷检测结果进行分析,并使用射线检测方法进行验证,总结了该类疑似伪缺陷的特征,证明了从两侧同时检测时,水平定位在焊缝中心远离探头一侧的疑似缺陷为伪缺陷。
Abstract
Through analysis of the suspected defect by ultrasonic testing of small diameter tube, and the use of X-ray detection and verification, the characteristics of the suspected false defects were summarized. And it was concluded that if the test was performed at the same time from both sides, the one with its horizontal positioning being in the weld center of far away from the probe side was likely to be the pseudo defect.
中图分类号 TG115.28 DOI 10.11973/wsjc201709009
所属栏目 试验研究
基金项目
收稿日期 2016/12/14
修改稿日期
网络出版日期
作者单位点击查看
联系人作者赵飞(897689395@qq.com)
备注赵飞(1989-),男,本科,助理工程师,主要从事电力工程检测试验方面的工作
引用该论文: ZHAO Fei,RUAN Yuming,HUA Lei. Discrimination of False Defects in Ultrasonic Testing of Small Diameter Pipes[J]. Nondestructive Testing, 2017, 39(9): 39~40
赵飞,阮玉明,华磊. 小径管超声检测中伪缺陷的判别[J]. 无损检测, 2017, 39(9): 39~40
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】NB/T 47013-2015 承压设备无损检测[S].
【2】吴刚, 罗晓明,胡文杰,等.小口径薄壁压力管道对接焊缝超声检测[J].无损检测, 2004,26(6):285-287.
【3】GB/T 11345-2013 焊缝无损检测 超声检测 技术、检测等级和评定[S].
【4】DL/T 820-2002 管道焊接接头超声检验技术规程[S].
【5】DL/T 821-2002 钢制承压管道对接焊接接头射线检验技术规程[S].
【2】吴刚, 罗晓明,胡文杰,等.小口径薄壁压力管道对接焊缝超声检测[J].无损检测, 2004,26(6):285-287.
【3】GB/T 11345-2013 焊缝无损检测 超声检测 技术、检测等级和评定[S].
【4】DL/T 820-2002 管道焊接接头超声检验技术规程[S].
【5】DL/T 821-2002 钢制承压管道对接焊接接头射线检验技术规程[S].