Influence of Permeability Temperature on Sensitivity during Fluorescent Penetrant Testing and Its Countermeasures
摘 要
针对荧光渗透检测时较低的渗透温度会影响检测灵敏度的问题,对荧光渗透液的黏度等物理参数进行了试验,了解了荧光渗透液温度、黏度、检测工艺、水处理之间的关系。结果表明:选取15~35 ℃的温度范围对渗透检验是比较适宜的。最后提出了荧光渗透槽温度的改造方案,可以保证渗透检测的灵敏度。
Abstract
In order to solve the problem that low fluorescence permeability temperature will influent the sensitivity of fluorescent penetrant, the physical parameters such as viscosity and so on were tested, and the relationship between temperature, viscosity, fluorescence penetrant detection technology and water treatment was understood. The results show that the temperature range of 15~35 ℃ is suitable for penetrant inspection. Finally, a scheme for improving the temperature of the fluorescent permeation tank is proposed to ensure the sensitivity of the penetrant inspection.
中图分类号 TG115.28 DOI 10.11973/wsjc201709020
所属栏目 实践经验
基金项目
收稿日期 2017/1/18
修改稿日期
网络出版日期
作者单位点击查看
联系人作者董务江(ndt01@sina.com)
备注董务江(1953-),男,主要从事无损检测工作
引用该论文: DONG Wujiang,HU Cheng,FENG Peijun. Influence of Permeability Temperature on Sensitivity during Fluorescent Penetrant Testing and Its Countermeasures[J]. Nondestructive Testing, 2017, 39(9): 80~82
董务江,胡诚,冯佩军. 荧光渗透检测中渗透温度对灵敏度的影响及其对策[J]. 无损检测, 2017, 39(9): 80~82