Effect Evaluation of Solid State Decoupler Used for Mitigotion of AC Interference
摘 要
受高压交流输电线路接地极影响,三层聚乙烯防腐蚀层(3LPE)管道容易受到较强的交流干扰,通常采取"固态去耦合器+接地极"的减缓措施。通过对交流减缓效果、阴极保护效果、排流影响范围、直流漏流量等现场参数进行测试,全面介绍了一种固态去耦合器性能评价方案,并指出现有固态去耦合器在使用过程中存在过度设计及故障电流下铜接地极易出现电偶腐蚀等风险。
Abstract
"Solid state decoupler + copper grounding", as a common AC mitigation measurement, is often used in underground pipelines which are coated with three layer polyethylene coating and affected by grounding of adjacent high voltage AC transmission lines. A comprehensive solid state decoupler evaluation is introduced by means of the field parameter test of AC mitigation performance, cathodic protection and DC leakage. The risk of excessive design and copper grounding prone to galvanic corrosion is also pointed.
中图分类号 TE988 DOI 10.11973/fsyfh-201711014
所属栏目 应用技术
基金项目
收稿日期 2016/3/20
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: SONG Xiaoqing,WANG Wenqiang,LAN Wei,XU Chengwei. Effect Evaluation of Solid State Decoupler Used for Mitigotion of AC Interference[J]. Corrosion & Protection, 2017, 38(11): 885
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】胡士信. 阴极保护工程手册[M]. 北京:化学工业出版社,1999.
【2】张平,童开平,屠海波,等. 陕京三线交流干扰防护新技术应用及优化[J]. 腐蚀与防护,2012,33(8):724-727.
【3】茅斌辉,王胜炎,胡士信,等. 强电线路下的阴极保护管道交流干扰防护措施[J]. 腐蚀与防护,2015,36(3):281-285.
【4】GB/T 50698-2011埋地钢质管道交流干扰防护技术标准[S].
【5】NACE SP0177-2014 Mitigation of alternating current and lightning effects on metallic structures andcorrosion control systems[S].
【6】高安东. 固态去耦合器交流干扰减缓效果检测[J]. 腐蚀与防护,2013,34(1):95-97.
【7】张平. 集中接地降低管道上的交流干扰电压[J]. 腐蚀与防护,2013,34(2):168-173.
【8】刘国. 固态去耦合器在管道交流干扰防护中的应用[J]. 油气储运.
【9】SEGALL S M,GUMMOW R A A. Ensuring the accuracy of indirect inspections data in the ECDA process[C]//Corrosion 2010. San Antonio:[s.n.],2010:10061.
【10】杜艳霞,沙晓东,刘骁. 江西天然气管道交流干扰检测与防护[J]. 油气储运,2014,33(1):56-60.
【2】张平,童开平,屠海波,等. 陕京三线交流干扰防护新技术应用及优化[J]. 腐蚀与防护,2012,33(8):724-727.
【3】茅斌辉,王胜炎,胡士信,等. 强电线路下的阴极保护管道交流干扰防护措施[J]. 腐蚀与防护,2015,36(3):281-285.
【4】GB/T 50698-2011埋地钢质管道交流干扰防护技术标准[S].
【5】NACE SP0177-2014 Mitigation of alternating current and lightning effects on metallic structures andcorrosion control systems[S].
【6】高安东. 固态去耦合器交流干扰减缓效果检测[J]. 腐蚀与防护,2013,34(1):95-97.
【7】张平. 集中接地降低管道上的交流干扰电压[J]. 腐蚀与防护,2013,34(2):168-173.
【8】刘国. 固态去耦合器在管道交流干扰防护中的应用[J]. 油气储运.
【9】SEGALL S M,GUMMOW R A A. Ensuring the accuracy of indirect inspections data in the ECDA process[C]//Corrosion 2010. San Antonio:[s.n.],2010:10061.
【10】杜艳霞,沙晓东,刘骁. 江西天然气管道交流干扰检测与防护[J]. 油气储运,2014,33(1):56-60.
相关信息