Elongation Testing Accuracy of Metals
摘 要
通过介绍不同引伸计的测试特点、使用的注意事项及测试精度,着重阐述了测试过程中仪器的精度对金属延伸率测试结果的影响,并通过对相关标准的解析得出,测量器具的精度不能代表延伸率的测试精度,选择合适的测量器具才能得到准确的测试结果。
Abstract
The effect of instrument accuracy on elongation testing results of metals was mainly discussed by introducing measuring characteristics, points for attention and the testing accuracy of different extensometer. Combined with the analysis of the relative standards, it is concluded that:the instrument accuracy could not represent the accuracy of elongation testing, and the accurate testing results would be obtained by selecting the appropriate testing instruments.
中图分类号 TG115.5+2 DOI 10.11973/lhjy-wl201801006
所属栏目 试验技术与方法
基金项目
收稿日期 2017/5/2
修改稿日期
网络出版日期
作者单位点击查看
备注许佳佳(1986-),男,工程师,主要从事汽车零部件及汽车电子组装产品的质量检验和失效分析等方面的研究,xujiajia@mttlab.com
引用该论文: XU Jiajia. Elongation Testing Accuracy of Metals[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2018, 54(1): 25~27
许佳佳. 金属延伸率的测试精度[J]. 理化检验-物理分册, 2018, 54(1): 25~27
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】宁青菊,谈国强,史永胜. 无机材料物理性能[M]. 北京:化学工业出版社,2006.
【2】吴伟,杨宏飞. DC03冷轧钢板断后伸长率测试结果的影响因素及其不确定度评定[J]. 理化检验(物理分册),2017,53(5):314-318.
【3】李凌梅,戴庆生,刘红光,等. 引伸计的简述和检修[J]. 国外电子测量技术,2017,36(6):117-120.
【4】彭真. 接触与非接触式引伸计自动测定冷轧薄板断后伸长率的结果比较[J]. 金属材料与冶金工程,2010,38(5):30-32.
【5】宋国斌,甘敏. GSYB型光栅数显式引伸计标定仪示值误差的测量不确定度评定及符合性评价[J]. 计量与测试技术,2013,40(7):50-51.
【6】陈吉祥. 如何提高伸长率的测量精度[J]. 上海计量测试,1988(4):32-33.
【2】吴伟,杨宏飞. DC03冷轧钢板断后伸长率测试结果的影响因素及其不确定度评定[J]. 理化检验(物理分册),2017,53(5):314-318.
【3】李凌梅,戴庆生,刘红光,等. 引伸计的简述和检修[J]. 国外电子测量技术,2017,36(6):117-120.
【4】彭真. 接触与非接触式引伸计自动测定冷轧薄板断后伸长率的结果比较[J]. 金属材料与冶金工程,2010,38(5):30-32.
【5】宋国斌,甘敏. GSYB型光栅数显式引伸计标定仪示值误差的测量不确定度评定及符合性评价[J]. 计量与测试技术,2013,40(7):50-51.
【6】陈吉祥. 如何提高伸长率的测量精度[J]. 上海计量测试,1988(4):32-33.