Effect of Nitric Acid Concentration on Intergranular Corrosion of 5083-H116 Aluminum Alloy Plates
摘 要
在不同含量硝酸溶液中对6 mm厚5083-H116铝合金板材进行晶间腐蚀试验,通过测量质量损失的方法来衡量其晶间腐蚀敏感性。结果表明:随着硝酸含量降低,5083-H116铝合金板材的晶间腐蚀倾向变大;当硝酸稀释至质量分数为51%时,质量损失已不满足≤15 mg/cm2的标准要求。
Abstract
Intergranular corrosion test was carried out for 5083-H116 aluminium alloy plates with thickness of 6 mm in nitric acid solution with different concentrations. The susceptibility to intergranular corrosion of 5083-H116 aluminium alloy plates was evaluated by mass loss method. The results show that the tendency to intergranular corrosion became large with the decrease of nitric acid concentration for 5083-H116 aluminium alloy plates. When nitric acid was diluted to 51% of mass fraction, the mass loss could not meet the standard requirement of no larger than 15 mg/cm2.
中图分类号 TG172 DOI 10.11973/fsyfh-201802009
所属栏目 试验研究
基金项目
收稿日期 2016/7/22
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: YANG Hongchi,LU Kecheng,LIU Junsheng,ZHOU Wenbiao. Effect of Nitric Acid Concentration on Intergranular Corrosion of 5083-H116 Aluminum Alloy Plates[J]. Corrosion & Protection, 2018, 39(2): 122