搜索热:失效分析 陶瓷
扫一扫 加微信
首页 > 期刊论文 > 论文摘要
电感耦合等离子体原子发射光谱法测定铀铌混合氧化物中镉、锡和锌
          
ICP-AES Determination of Cd, Sn and Zn in Uranium-Niobium Mixed Oxide

摘    要
铀铌混合氧化物样品0.200 0 g用硝酸8 mL,氢氟酸2 mL进行微波消解后,经苯乙烯-二乙烯苯-磷酸三丁酯萃取柱分离铀与镉、锡、锌,采用电感耦合等离子体原子发射光谱法测定淋洗液中镉、锡和锌的含量。选择镉、锡、锌的分析谱线依次为226.502,189.989,213.856 nm。3种元素的质量浓度均在一定范围内与其对应的发射强度呈线性关系,方法的检出限(3s)为0.003~0.02 mg·L-1。加标回收率为94.0%~101%,测定值的相对标准偏差(n=6)为3.7%~7.4%。
标    签 电感耦合等离子体原子发射光谱法   铀铌混合氧化物   元素   ICP-AES   uranium-niobium mixed oxide   element  
 
Abstract
The uranium-niobium mixed oxide sample (0.200 0 g) was digested with HNO3 (8 mL) and HF (2 mL) in microwave system. The CL-TBP extraction column was used to separate Cd, Sn and Zn from U. ICP-AES was applied to the determination of Cd, Sn and Zn in eluent. Analytical spectral lines of 226.502, 189.989 and 213.856 nm were chosen for the determination of Cd, Sn and Zn respectively. Linear relationships between values of emission intensity and mass concentration of the 3 elements were kept in definite ranges, with detection limits (3s) in the range of 0.003-0.02 mg·L-1. Values of recovery found by standard addition method were in the range of 94.0%-101%, and values of RSD's (n=6) in the range of 3.7%-7.4%.

中图分类号 O657.31   DOI 10.11973/lhjy-hx201802015

 
  中国光学期刊网论文下载说明


所属栏目 工作简报

基金项目

收稿日期 2017/2/3

修改稿日期

网络出版日期

作者单位点击查看

备注杨平(1969-),男,河南驻马店人,技师,研究方向为核燃料及材料化学分析,yp0610@163.com

引用该论文: YANG Ping,WANG Peng,FEI Hao,WANG Zhanming. ICP-AES Determination of Cd, Sn and Zn in Uranium-Niobium Mixed Oxide[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2018, 54(2): 196~199
杨平,王鹏,费浩,王占明. 电感耦合等离子体原子发射光谱法测定铀铌混合氧化物中镉、锡和锌[J]. 理化检验-化学分册, 2018, 54(2): 196~199


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】GB/T 13372-92二氧化铀粉末和芯块中杂质元素的测定(ICP-AES)[S].
 
【2】VIJAYALAKSHMI S, KRISHMA P R, MAHALINGAM T R, et al. Determination of trace metal by inductively coupled plasma mass specfrometry combined with on-line solvent extraction[J]. Journal of Analytical Atomic Spectrometry, 1992,7(3):565-569.
 
【3】FLOYD M A, MORROW R, FARRAR R B. Inductively coupled plasma-atomic emission spectroscopy the determination of trace impurities in uranium hexafluoride[J]. Spectrochimica Acta, 1983,38(1/2):303-308.
 
【4】费浩,倪智勇.八氧化三铀中锆测定方法的研究[J].光谱实验室, 2008,25(5):784-787.
 
【5】刘虎生,冯斌,潘彦霖.电感耦合等离子体发射光谱法测定八氧化三铀中痕量杂质元素[J].分析化学, 1991,19(2):203-206.
 
【6】吉艳琴,李金英,罗上庚.TOPO萃取色层分离-ICP-MS法测定土壤中痕量铀的同位素丰度比[J].核化学与放射化学, 2004,26(2):89-94.
 
【7】CROZET M, GUIGUE M. Separation of actinides by extraction chromatography prior to X-ray fluorescence measurement for analytical control of a purex test[J]. Radiochim, 2007,95:629-635.
 
【8】MORGENSTEM A, APOSTOLIDIS C, CARLOS-MARQUEZ R, et al. Single-column extraction chromatographic separation of U, Pu, Np and Am[J]. Radiochim Acta, 2002,90:81-85.
 
相关信息
   标题 相关频次
 电感耦合等离子体原子发射光谱法测定明矾石矿中11种元素的含量
 4
 电感耦合等离子体质谱法测定核级海绵锆中钨
 4
 微波消解-电感耦合等离子体原子发射光谱法测定膨润土中6种元素
 4
 微波消解试样-萃取色谱分离-电感耦合等离子体原子发射光谱法测定涂铌二氧化铀微球中10种痕量元素
 4
 直接注入高效雾化器-电感耦合等离子体原子发射光谱法测定船用燃料油中26种元素
 4
 电感耦合等离子体原子发射光谱法测定钨矿石中硅、铁、铝、钛、钨、锡和钼的含量
 3
 高压密闭酸溶-电感耦合等离子体原子发射光谱法测定锑矿石中10种元素
 3
 混合酸溶解-电感耦合等离子体原子发射光谱法测定土壤中17种元素
 3
 五酸消解-电感耦合等离子体原子发射光谱法测定矽卡岩型多金属钨矿中钨、钼、铋的含量
 3
 轴向观测电感耦合等离子体原子发射光谱法测定天然纺织纤维中24种元素
 3
 630 MW超临界锅炉高温过热器管爆管原因
 2
 Chelex 100树脂固相萃取-电感耦合等离子体原子发射光谱法测定高氯高盐废水中6种重金属元素
 2
 ICP-AES法测定进口氧化铝中杂质元素含量
 2
 ICP-AES法测定我国三个不同地域生长的板栗中20种元素
 2
 ICP-AES法同时测定搪瓷餐具中铅镉锑镍的溶出量
 2
 P110钢级油管接箍开裂失效分析
 2
 X射线荧光光谱法半定量和电感耦合等离子体质谱法全定量快速测定花草茶中多种元素
 2
 X射线荧光光谱法测定石膏中11种元素的含量
 2
 X射线荧光光谱法测定新研制土壤标准物质中11种元素的含量
 2
 表面粗糙度对800H合金在超临界水环境中腐蚀行为的影响
 2
 玻璃钢管试压渗漏的原因
 2
 玻璃钢集油管道泄漏原因
 2
 不同材料金属橡胶在中性盐液中的耐腐蚀及阻尼性能
 2
 不同混合酸消解样品对电感耦合等离子体原子发射光谱法测定土壤中重金属含量的影响
 2
 超超临界火电机组热交换器BFe10-1-1白铜管泄漏分析
 2
 超级微波消解-全自动重金属分析联用系统测定土壤中18种元素的含量
 2
 超临界二氧化碳环境中800H合金的均匀腐蚀行为
 2
 沉淀分离金-电感耦合等离子体原子发射光谱法测定镀金溶液中铁、钴、镍、铜、银、铅
 2
 传统手工纸中9种金属元素的电感耦合等离子体原子发射光谱法测定及其溯源研究
 2
 大口径X70感应加热试制弯管的组织与性能
 2