Influence Factor Analysis and Measurement Uncertainty Evaluation on Oxidation Induction Time of Plastics
摘 要
以一种黑色聚乙烯颗粒为研究对象,依据GB/T 19466.6-2009测定样品在220 ℃恒温时的氧化诱导期,探讨了样品质量、恒温温度、氧气流量等参数对测定结果的影响,并依据JJF 1059.1-2012对测定过程中引入的标准不确定度分量进行了评定。结果表明:影响氧化诱导期测定结果的最主要因素是测量重复性和恒温温度,氧气流量和样品质量对测定结果的影响较小;利用差示扫描量热法测定的该聚乙烯氧化诱导期的扩展不确定度U=1.5 min(包含因子k=2)。
Abstract
Taking a black polyethylene particles as the research object, according to GB/T 19466.6-2009, the oxidation induction time (OIT) of the sample at a constant temperature of 220℃ was measured, and the influence of the sample mass, constant temperature, oxygen flow rate and other parameters on the measurement result was discussed. And then the standard uncertainty components introduced during the measurement were evaluated according to JJF 1059.1-2012. The results show that the most important factors affecting the OIT measurement results were measurement repeatability and constant temperature, and oxygen flow and sample mass had little effect on the measurement results. The expanded uncertainty of OIT of the polyethylene measured by differential scanning calorimetry method was as following:U=1.5 min when the coverage factor k=2.
中图分类号 TQ320.7 DOI 10.11973/lhjy-wl201806009
所属栏目 试验技术与方法
基金项目
收稿日期 2018/1/4
修改稿日期
网络出版日期
作者单位点击查看
备注孟祥艳(1983-),女,副研究员,主要从事非金属材料的性能表征与国防化学计量工作,mengxy79@126.com
引用该论文: MENG Xiangyan,WANG Xuerong,WANG Qianqian,WANG Kang,ZHOU Yanping,LIU Yunchuan. Influence Factor Analysis and Measurement Uncertainty Evaluation on Oxidation Induction Time of Plastics[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2018, 54(6): 427~430
孟祥艳,王雪蓉,王倩倩,王康,周燕萍,刘运传. 塑料氧化诱导期影响因素分析及其测量不确定度评定[J]. 理化检验-物理分册, 2018, 54(6): 427~430
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】胡小锋. 防老剂D与BHT标准物质的研制及橡胶热氧老化研究[D]. 西安:西北工业大学,2004.
【2】陈键. 聚丙烯耐热氧老化性能的研究[D]. 广州:仲恺农业工程学院,2015.
【3】郭华. 抗氧剂在聚苯乙烯中的应用研究[D]. 沈阳:沈阳工业大学,2015.
【4】詹威鹏,褚学来,申作家,等. 加速热氧老化中交联聚乙烯电缆绝缘聚集态结构与介电强度关联性研究[J]. 中国电机工程学报,2016,36(17):4770-4778.
【5】刘金霞,张其滨,徐翠竹,等. 聚乙烯热收缩带氧化诱导期与热老化性能的关系[J]. 腐蚀与防护,2016,37(8):657-659,665.
【6】CIBULKOVÁ Z,ŠIMON P,LEHOCK AY'G P, et al. DSC study of antioxidant activity of selected p-phenylenediamines in styrene-butadiene rubber[J]. Journal of Thermal Analysis and Calorimetry,2009,97(2):535-540.
【7】郭思敏,汤晓英,左延田,等. 受火损伤后聚乙烯管道合乎使用评定方法与进展[J]. 理化检验(物理分册),2017,53(4):235-239,252.
【8】张立军,马子贵,姜进宪,等. 塑料氧化诱导时间和氧化诱导温度的标准试验方法综述[J]. 橡塑技术与装备,2009,35(3):5-9.
【9】董宝钧,张立军,高海,等. 差示扫描量热法测定聚烯烃的氧化诱导时间[J]. 橡塑技术与装备,2010,36(11):25-27.
【10】冉学臣. 疲劳试验结果测量不确定度评定[J]. 理化检验(物理分册),2017,53(10):717-719.
【11】ELSTER C. Bayesian uncertainty analysis compared with the application of the GUM and its supplements[J]. Metrologia,2014,51(4):159-166.
【2】陈键. 聚丙烯耐热氧老化性能的研究[D]. 广州:仲恺农业工程学院,2015.
【3】郭华. 抗氧剂在聚苯乙烯中的应用研究[D]. 沈阳:沈阳工业大学,2015.
【4】詹威鹏,褚学来,申作家,等. 加速热氧老化中交联聚乙烯电缆绝缘聚集态结构与介电强度关联性研究[J]. 中国电机工程学报,2016,36(17):4770-4778.
【5】刘金霞,张其滨,徐翠竹,等. 聚乙烯热收缩带氧化诱导期与热老化性能的关系[J]. 腐蚀与防护,2016,37(8):657-659,665.
【6】CIBULKOVÁ Z,ŠIMON P,LEHOCK AY'G P, et al. DSC study of antioxidant activity of selected p-phenylenediamines in styrene-butadiene rubber[J]. Journal of Thermal Analysis and Calorimetry,2009,97(2):535-540.
【7】郭思敏,汤晓英,左延田,等. 受火损伤后聚乙烯管道合乎使用评定方法与进展[J]. 理化检验(物理分册),2017,53(4):235-239,252.
【8】张立军,马子贵,姜进宪,等. 塑料氧化诱导时间和氧化诱导温度的标准试验方法综述[J]. 橡塑技术与装备,2009,35(3):5-9.
【9】董宝钧,张立军,高海,等. 差示扫描量热法测定聚烯烃的氧化诱导时间[J]. 橡塑技术与装备,2010,36(11):25-27.
【10】冉学臣. 疲劳试验结果测量不确定度评定[J]. 理化检验(物理分册),2017,53(10):717-719.
【11】ELSTER C. Bayesian uncertainty analysis compared with the application of the GUM and its supplements[J]. Metrologia,2014,51(4):159-166.
相关信息