Se75 Ray Source Inspection of Thin-Walled Pipe Welds of Nuclear Power Plant Based on RCC-M Specification
摘 要
通过射线透照对比试验,验证了采用Se75射线源对核电厂薄壁管道焊缝进行射线检测的像质计灵敏度,比较了Se75和Ir192射线源照相的特性,以及不同射线源在满足RCC-M《压水堆核岛机械设备设计和建造规则》规范时射线透照工艺参数下的照相灵敏度;提出了Se75射线照相适用的厚度范围,验证了Se75射线源在满足RCC-M规范的射线透照工艺参数下与不同种类胶片和增感屏组合系统的照相灵敏度,推荐了Se75射线源检测适用的胶片种类。
Abstract
Radiographic tests by using Se75 ray source were used to verify the detection penetrameter sensitivity for nuclear power plant of thin-walled piping welds. By comparing the photographic characteristics of Se75 with Ir192 ray source, as well as photographic sensitivities for different radiation sources to meet the RCC-M The Design and Construction Rules Applicable to Mechanical Components of PWR Nuclear Islands specifications, applicable thickness rang of Se75 radiography was proposed, verified the photographic sensitivity while using Se75 ray source with different types of film and intensifying screen together to meet the RCC-M specification. The applicable radiographic film types while using Se75 ray source were recommended.
中图分类号 TG115.28 DOI 10.11973/wsjc201807005
所属栏目 试验研究
基金项目
收稿日期 2017/11/28
修改稿日期
网络出版日期
作者单位点击查看
备注李学军(1981-),男,硕士,主要从事核电厂机械部件材料及无损检测设计工作
引用该论文: LI Xuejun,WU Weibang,CHEN Hang,ZHANG Jin. Se75 Ray Source Inspection of Thin-Walled Pipe Welds of Nuclear Power Plant Based on RCC-M Specification[J]. Nondestructive Testing, 2018, 40(7): 22~26
李学军,吴伟帮,陈航,张进. 基于RCC-M规范的核电厂薄壁管道焊缝的Se75射线源检测[J]. 无损检测, 2018, 40(7): 22~26
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】李家伟,陈积霖. 无损检测手册[M].北京:机械工业出版社,2006.
【2】郑世才. 我国射线检测技术发展[J].无损检测,2004,26(4):163-167.
【2】郑世才. 我国射线检测技术发展[J].无损检测,2004,26(4):163-167.