Determination of Equivalent Coefficient of Digital Ray Detection for Ceramic Materials and Aluminum Alloy
摘 要
为了获得陶瓷材料与铝合金X射线数字成像(DR)检测的等效系数,在透照电压为60 kV~90 kV时,分别对不同厚度的陶瓷和铝合金进行数字射线透照,得到其X射线穿透率与透照厚度的关系曲线,并拟合得到相应公式;射线透照率相同条件下的陶瓷厚度与铝合金厚度互为等效厚度,进而可以确定其等效系数,对陶瓷材料的射线检测具有一定的指导意义。
Abstract
In order to obtain the equivalent coefficient of X-ray digital radiography (DR) detection for ceramic materials and aluminum alloy, corresponding X-ray digital radiography tests were undertaken for different thickness of ceramics and aluminum alloy respectively, under transmission voltage of 60 kV-90 kV. The X-ray penetration rate curves of ceramic and aluminum alloy were obtained, and the corresponding formula was fitted. The equivalent thickness of ceramic and aluminum alloy was defined as having the same rate of radiographic penetration rate, and in accordance with that, the equivalent coefficient of thickness for the two materials was then determined. It has a certain guiding significance for X-ray detection of ceramic materials.
中图分类号 TG115.28 DOI 10.11973/wsjc201807009
所属栏目 试验研究
基金项目
收稿日期 2017/11/29
修改稿日期
网络出版日期
作者单位点击查看
联系人作者赵付宝(qdzfb@163.com)
备注赵付宝(1979-),男,硕士,副研究员,主要从事非金属及复合材料的X射线无损检测应用技术研究工作
引用该论文: ZHAO Fubao,WANG Congke,TANG Zhenhe,DONG Fangxu,FAN Limei. Determination of Equivalent Coefficient of Digital Ray Detection for Ceramic Materials and Aluminum Alloy[J]. Nondestructive Testing, 2018, 40(7): 39~42
赵付宝,王从科,汤振鹤,董方旭,凡丽梅. 陶瓷材料与铝合金数字射线检测等效系数的确定[J]. 无损检测, 2018, 40(7): 39~42
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】张自强.装甲防护技术基础[M].北京:兵器工业出版社,2000.
【2】张新杰. 影响陶瓷装甲抗弹性能的主要因素[J].兵工学报,2012,27(2):103-106.
【3】郑世才.数字射线检测技术专题(一)——概述[J].无损检测,2012,34(1):49-51.
【4】郑世才,王晓勇.数字射线检测技术[M].北京:机械工业出版社,2015.
【2】张新杰. 影响陶瓷装甲抗弹性能的主要因素[J].兵工学报,2012,27(2):103-106.
【3】郑世才.数字射线检测技术专题(一)——概述[J].无损检测,2012,34(1):49-51.
【4】郑世才,王晓勇.数字射线检测技术[M].北京:机械工业出版社,2015.