Determination of Total Arsenic in Salt Saturated Water by Inductively Coupled Plasma Mass Spectrometry with Online Dilution with Argon
摘 要
应用氩气在线稀释克服了电感耦合等离子体质谱法直接测定饱和食盐水中总砷时高盐的基体效应。运用碰撞池技术,有效消除40Ar35Cl+对砷的干扰;通过在线加入甲醇溶液,提高砷的灵敏度。试验结果表明:砷的线性范围在10.0 μg·L-1以内,检出限(3s)为0.092 μg·L-1,加标回收率在90.2%~111%之间,测定值的相对标准偏差(n=6)在1.7%~4.2%之间。
Abstract
Online dilution with argon was applied to direct determination of total arsenic in salt saturated water by inductively coupled plasma mass spectrometry to overcome matrix effect of high salt containing sample. The interference of 40Ar35Cl+ to arsenic was reduced by using collision cell technique. Sensitivity of arsenic was raised by adding methanol solution. As shown by the results, the linearity range of arsenic was within 10.0 μg·L-1, with detection limit (3s) of 0.092 μg·L-1. Values of recovery obtained by standard addition method were in the range of 90.2%-111%, and RSDs (n=6) were in the range of 1.7%-4.2%.
中图分类号 O657.63 DOI 10.11973/lhjy-hx201809022
所属栏目 专题报道(高关注物质)
基金项目 国家重点研发计划“重大科学仪器设备开发”重点专项(2016YFF0100200;2017YFF0108203)
收稿日期 2017/10/10
修改稿日期
网络出版日期
作者单位点击查看
备注李鹰,工程师,主要从事光谱仪器应用方法研究,ying_li06450@fpi-inc.com
引用该论文: LI Ying,YU Xiaofeng,LI Jian,LIAN Yan,LU Shuimiao. Determination of Total Arsenic in Salt Saturated Water by Inductively Coupled Plasma Mass Spectrometry with Online Dilution with Argon[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2018, 54(9): 1088~1091
李鹰,俞晓峰,李剑,梁炎,卢水淼. 氩气在线稀释-电感耦合等离子体质谱法直接测定饱和食盐水中总砷[J]. 理化检验-化学分册, 2018, 54(9): 1088~1091
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王丹红,林建杰,蔡春平,等.在线分离富集-ICP-MS法直接测定海水中痕量稀土元素[J].分析试验室, 2016,35(7):773-775.
【2】林继军,段华玲,弓振斌.聚乙烯亚胺螯合-超滤分离富集电感耦合等离子体质谱法测定海水中6种痕量金属元素[J].分析化学, 2011,39(6):906-910.
【3】刘莹,翟世奎,张爱滨,等.直接稀释法ICP-MS测定海水中溶解态痕量重金属[J].海洋学报, 2008,30(5):151-158.
【4】彭荣飞,黄聪,卓召模,等,碰撞池ICP-MS测定近海海水中的Cr、As、Se、Cd、Cu、Zn、Hg和Pb[J].中国卫生检验杂志, 2008,18(12):2529-2531.
【5】韦新红,何龙凉,谢毓群,等.碰撞反应界面-电感耦合等离子体质谱法直接测定海水中7种元素[J].广西科学, 2013,20(3):230-233.
【6】PLANTZ M R, FRITZ J S, SMITH F G, et al. Separation of trace metal complexes for analysis of samples of high salt content by inductively coupled plasma mass spectrometry[J]. Analiytical Chemistry, 1989,61(2):149-153.
【7】杨朝勇,陈发荣,庄峙厦,等.微柱固相萃取-电感耦合等离子体质谱联用技术用于测定高盐样品中痕量的铅[J].厦门大学学报(自然科学版), 2001,40(5):1062-1066.
【8】荆淼,陈诚详,张建平,等.同位素稀释电感耦合等离子体质谱测定环境和生物样品中的镉[J].环境化学, 2010,29(5):986-989.
【9】王征,荆淼,黎先春,等.8-羟基喹啉-硅胶介质的合成及其在海水中痕量铅检测的应用[J].分析化学, 2006,34(4):459-463.
【10】张江义,郭伟,李国敏.动态反应池-电感耦合等离子体质谱法直接测定高盐氯化钙型地下水中的痕量总砷[J].分析化学, 2013,41(12):1915-1918.
【11】母清林,方杰,佘运勇,等.在线稀释/预浓缩-电感耦合等离子体质谱法分析海水中11种痕量元素[J].分析化学, 2015,43(9):1360-1363.
【12】陈光,林立,陈玉红.液相色谱-电感耦合等离子体质谱法联用测定乳制品的无机砷及其它砷形态[J].环境化学, 2009,28(4):609-670.
【2】林继军,段华玲,弓振斌.聚乙烯亚胺螯合-超滤分离富集电感耦合等离子体质谱法测定海水中6种痕量金属元素[J].分析化学, 2011,39(6):906-910.
【3】刘莹,翟世奎,张爱滨,等.直接稀释法ICP-MS测定海水中溶解态痕量重金属[J].海洋学报, 2008,30(5):151-158.
【4】彭荣飞,黄聪,卓召模,等,碰撞池ICP-MS测定近海海水中的Cr、As、Se、Cd、Cu、Zn、Hg和Pb[J].中国卫生检验杂志, 2008,18(12):2529-2531.
【5】韦新红,何龙凉,谢毓群,等.碰撞反应界面-电感耦合等离子体质谱法直接测定海水中7种元素[J].广西科学, 2013,20(3):230-233.
【6】PLANTZ M R, FRITZ J S, SMITH F G, et al. Separation of trace metal complexes for analysis of samples of high salt content by inductively coupled plasma mass spectrometry[J]. Analiytical Chemistry, 1989,61(2):149-153.
【7】杨朝勇,陈发荣,庄峙厦,等.微柱固相萃取-电感耦合等离子体质谱联用技术用于测定高盐样品中痕量的铅[J].厦门大学学报(自然科学版), 2001,40(5):1062-1066.
【8】荆淼,陈诚详,张建平,等.同位素稀释电感耦合等离子体质谱测定环境和生物样品中的镉[J].环境化学, 2010,29(5):986-989.
【9】王征,荆淼,黎先春,等.8-羟基喹啉-硅胶介质的合成及其在海水中痕量铅检测的应用[J].分析化学, 2006,34(4):459-463.
【10】张江义,郭伟,李国敏.动态反应池-电感耦合等离子体质谱法直接测定高盐氯化钙型地下水中的痕量总砷[J].分析化学, 2013,41(12):1915-1918.
【11】母清林,方杰,佘运勇,等.在线稀释/预浓缩-电感耦合等离子体质谱法分析海水中11种痕量元素[J].分析化学, 2015,43(9):1360-1363.
【12】陈光,林立,陈玉红.液相色谱-电感耦合等离子体质谱法联用测定乳制品的无机砷及其它砷形态[J].环境化学, 2009,28(4):609-670.
相关信息