Effect of contrast enhancer thickness on detection rate of defects in magnetic particle test
摘 要
磁粉检测时,如果磁粉与工件表面的颜色对比度小,则容易造成小缺陷漏检。为了提高磁粉检测时的缺陷检出率,可在工件表面喷涂反差增强剂以提高对比度。试验研究了反差增强剂厚度对缺陷检出率的影响。结果表明:一定厚度的反差增强剂,可以提高对比度,对缺陷检出率的影响很小。
Abstract
In magnetic particle testing, if the color contrast between magnetic powder and the workpiece surface is small, it is easy to cause some small defects being undetected. In order to improve the defect detection rate of magnetic powder, the contrast agent can be sprayed on the surface of the workpiece to improve the contrast. The effect of contrast enhancer thickness on defect detection rate was studied experimentally. The results show that the contrast enhancer with a certain thickness can improve the contrast but it has little effect on the defect detection rate.
中图分类号 TG115.28 DOI 10.11973/wsjc202004009
所属栏目 试验研究
基金项目
收稿日期 2019/8/30
修改稿日期
网络出版日期
作者单位点击查看
备注王玉雄(1986-),男,工程师,主要研究方向为无损检测及质量管理
引用该论文: WANG Yuxiong,TAN Yunhua,WU Zhibo,XIE Jin,HAO Chunxia. Effect of contrast enhancer thickness on detection rate of defects in magnetic particle test[J]. Nondestructive Testing, 2020, 42(4): 42~45
王玉雄,谭云华,吴志波,谢进,郝春霞. 反差增强剂厚度对磁粉检测缺陷检出率的影响[J]. 无损检测, 2020, 42(4): 42~45